Especificaciones técnicas
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Short-circuit protection | Yes |
| Isolation tested with | 707 V DC (type test) |
Datos eléctricos
| Mains/voltage failure stored energy time | 10 ms |
|---|---|
| Current consumption (rated value) | 550 mA |
| Current consumption, max. | 650 mA |
| Inrush current, max. | 1A |
| Power loss, typ. | 2W |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Entradas/Salidas y comunicación
| PROFINET from GSD version/GSD revision | GSDML V2.45 |
|---|---|
| Number of PROFINET interfaces | 1; 2 ports (switch) |
| RJ 45 (Ethernet) | Yes; with BusAdapter |
| BusAdapter (PROFINET) | Yes; BA 2x RJ45, BA 2x M12, BA 2x FC |
| PROFINET IO device | Yes |
| Supports protocol for PROFINET IO | Yes |
| PROFIsafe | Yes |
| EtherNet/IP | Yes |
| Modbus TCP | Yes |
| PROFINET system redundancy (S2) | Yes; NAP S2 |
| between PROFINET and all other circuits | Yes; 1500 V AC (type test) |
| PROFINET Security Class | 1 |
Otras características
| Product type designation | IM 155-6 MF HF |
|---|---|
| Firmware version | V6.4.1 |
| FW update possible | Yes |
| Vendor identification (VendorID) | 002AH |
| Device identifier (DeviceID) | 0313H |
| Device ID according to ODVA (Product code) | 0FA2H |
| I&M data | Yes; I&M0 to I&M4 |
| Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| Isochronous mode | Yes |
| IRT | Yes |
| Tool changer | Yes; Docking station and docking unit |
| Local coupling, IO data | Yes |
| Number of coupling modules | 6; 1x output + max. 5x input |
| STEP 7 TIA Portal configurable/integrated from version | V20 |
| STEP 7 configurable/integrated from version | V5.7 SP3 |
| Multi Fieldbus Configuration Tool (MFCT) | V1.5.2.0 or higher |
| via dataset | Yes |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| I²t | 0.05 A²·s |
| Address space per module, max. | 288 byte; For input and output data respectively |
| Address space per station, max. | 1 440 byte |
| Quantity of operable ET 200SP modules, max. | 64 |
| Quantity of operable ET 200AL modules, max. | 16 |
| Number of submodules per station, max. | 256 |
| Transmission procedure | 100BASE-TX |
| Number of ports | 2; with BusAdapter |
| integrated switch | Yes |
| Open IE communication | Yes |
| Media redundancy | Yes; PROFINET MRP client |
| Dynamic Frame Packing (DFP) | Yes |
| Fast Forwarding | Yes |
| Fragmentation | Yes |
| PROFIenergy | Yes |
| Prioritized startup | Yes |
| Shared device | Yes |
| Number of IO Controllers with shared device, max. | 14; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| 100 Mbps | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Number of MtM communication | 16 |
| H-Sync forwarding | Yes |
| MRP | Yes |
| MRPD | Yes |
| CIP Implicit Messaging | Yes |
| CIP Explicit Messaging | Yes |
| Number of scanners with shared device, max. | 2 |
| Requested Packet Interval (RPI) | 2 ms |
| ForwardOpen (Class1 & 32 bit Header) | 500 byte; (246 byte outputs / 500 byte inputs) |
| LargeForwardOpen (Class3) | 4 002 byte |
| Number of rack connections | 2 |
| read coils (code=1) | Yes |
| read discrete inputs (code=2) | Yes |
| Read Holding Registers (Code=3) | Yes |
| Read Input Register (Code=4) | Yes |
| write single coil (code=5) | Yes |
| Write Single Register (Code=6) | Yes |
| write multiple coils (code=15) | Yes |
| Write Multiple Registers (Code=16) | Yes |
| Read/Write Multiple Registers (Code=23) | Yes |
| Parameter change by master | Yes |
| Access-consistent address space | 250 byte; (246 byte outputs / 250 byte inputs) |
| I/O request interval | 2 ms |
| number of connections per device | 9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info) |
| TCP/IP | Yes |
| UDP | Yes |
| SNMP | Yes |
| LLDP | Yes |
| ARP | Yes |
| IGMP | Yes |
| Multicast | Yes |
| Broadcast | Yes |
| IPv4 | Yes |
| Equidistance | Yes |
| shortest clock pulse | 250 µs |
| max. cycle | 4 ms |
| Bus cycle time (TDP), min. | 250 µs |
| Jitter, max. | 1 µs |
| Status indicator | Yes |
| Alarms | Yes |
| Diagnostics function | Yes |
| RUN LED | Yes; green LED |
| ERROR LED | Yes; red LED |
| MAINT LED | Yes; Yellow LED |
| NS LED | Yes; green/red LED |
| MS LED | Yes; green/red LED |
| IO LED | Yes; red-green-yellow LED |
| Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter |
| between different circuits | Safety extra low voltage SELV |
| Network loading class | 3 |
| signed firmware update | Yes |
| safely removing data | Yes |
| data integrity | Yes |
| horizontal installation, min. | -30 °C; No condensation |
| horizontal installation, max. | 60 °C |
| vertical installation, min. | -30 °C; No condensation |
| vertical installation, max. | 50 °C |
| via BU/BA Send | Yes; + 16 ET 200AL modules |
| Strain relief | Yes; Optional |
| Width | 50 mm |
| Height | 117 mm |
| Depth | 74 mm |
| Weight, approx. | 120 g; without BusAdapter |
| last modified: | 6/18/2026 |