Especificaciones técnicas
Datos eléctricos
| operating voltage / maximum | 80 V |
|---|---|
| operating voltage / RMS value | 100 V |
| conductor cross section / of the power line | 0.34 mm² |
| continuous current / of the power lines | 5A |
Entradas/Salidas y comunicación
| wire length / with 100BaseTX / for Industrial Ethernet | 100 m |
|---|
Conexión y cableado
| cable designation | 2YH (ST) C 2x2x0.75/1.5LI LIH H 2x2x0.34/1.6GN FRNC |
|---|---|
| core diameter / of AWG22 insulated conductor | 0.76 mm |
| symmetrical tolerance of the outer diameter / of cable sheath | 0.4 mm |
Certificados y homologaciones
| UL/ETL listing / 300 V Rating | Yes; CMG / PLTC / SunRes |
|---|---|
| UL/ETL style / 600 V Rating | Yes |
| EAC approval | Yes |
| RoHS conformity | Yes |
Otras características
| product type designation | IE Hybrid Cable 2x2 + 4x0.34 |
|---|---|
| suitability for use | Ethernet hybrid cable for transfer of data and power |
| near-end crosstalk per length / at 1 MHz ... 100 MHz | 0.353 dB/m |
| transfer impedance per length / at 10 MHz | 10 mΩ/m |
| loop resistance per length / maximum | 120 Ω/km |
| insulation resistance coefficient | 500 GΩ·m |
| number of electrical cores | 8 |
| tensile load / maximum | 260 N |
| weight per length | 105 kg/km |
| fire behavior | flame-retardant according to IEC 60332-3-24 (Category C) |
| class of burning behaviour / according to EN 13501-6 | Eca |
| to mineral oil | Conditional resistance |
| to grease | Conditional resistance |
| to water | Conditional resistance |
| radiological resistance / to UV radiation | resistant |
| halogen-free | Yes |
| silicon-free | Yes |
| standard for structured cabling | Cat 5e (data cores), AWG 22 (power cores) |
| security | firmations |
| last modified: | 3/10/2026 |