Especificaciones técnicas
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Short-circuit protection | Yes |
| Isolation tested with | 707 V DC (type test) |
Datos eléctricos
| Mains/voltage failure stored energy time | 10 ms |
|---|---|
| Current consumption, max. | 335 mA |
| Inrush current, max. | 1.6 A |
| Power loss, typ. | 1.5 W |
| Output current of the interface, max. | 90 mA |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Entradas/Salidas y comunicación
| PROFIBUS from GSD version/GSD revision | si0181ab.gs* (V04.02.13, Rev.3, Rev.5) |
|---|---|
| Number of PROFIBUS interfaces | 1 |
| PROFIBUS DP device | Yes |
| PROFIsafe | Yes |
| PROFIBUS | Yes |
| between PROFIBUS DP and all other circuit components | Yes |
Condiciones ambientales
| Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
|---|
Otras características
| Product type designation | IM 155-6 DP HF |
|---|---|
| HW functional status | From FS02 |
| Firmware version | V4.2 |
| FW update possible | Yes |
| I&M data | Yes; I&M0 to I&M3 |
| Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| STEP 7 TIA Portal configurable/integrated from version | V15 SP1 |
| STEP 7 configurable/integrated from version | V5.5 SP4, only up to FW V3.1 |
| via dataset | Yes |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| I²t | 0.038 A²·s |
| Address space per module, max. | 32 byte; For input and output data respectively |
| Address space per station, max. | 244 byte |
| Quantity of operable ET 200SP modules, max. | 32 |
| Quantity of operable ET 200AL modules, max. | 16 |
| RS 485 | Yes; 1 integrated RS 485 socket |
| Transmission rate, max. | 12 Mbit/s |
| SYNC capability | Yes |
| FREEZE capability | Yes |
| DPV0 | Yes |
| DPV1 | Yes |
| Status indicator | Yes |
| Alarms | Yes |
| Diagnostics function | Yes |
| RUN LED | Yes; green LED |
| ERROR LED | Yes; red LED |
| MAINT LED | Yes; Yellow LED |
| Connection display DP | Yes; green DP LED |
| between different circuits | Safety extra low voltage SELV |
| horizontal installation, min. | -25 °C; No condensation |
| horizontal installation, max. | 60 °C |
| vertical installation, min. | -25 °C; No condensation |
| vertical installation, max. | 50 °C |
| via BU/BA Send | Yes; + 16 ET 200AL modules |
| Width | 50 mm |
| Height | 117 mm |
| Depth | 74 mm |
| Weight, approx. | 150 g |
| Railway | Environment |
| ate | firmations |
| last modified: | 10/23/2025 |