ET 200SP, IM155-6PN/2 HF
Siemens

ET 200SP, IM155-6PN/2 HF

SIMATIC ET 200SP, PROFINET, módulo de interfaz 2 puertos IM 155-6PN/2 High Feature, 1 slot para BusAdapter, máx. 64 módulos de periferia y 16 módulos ET 200AL, redundancia S2, Multi Hot Swapping, 0,25 ms, modo isócrono, alivio de tracción PN opcional, módulo servidor incluido

🔌 ComunicaciónGSDML V2.43
Entradas/Salidas y comunicación
PROFINET from GSD version/GSD revisionGSDML V2.43
Number of PROFINET interfaces1; 2 ports (switch)
RJ 45 (Ethernet)Yes; with BusAdapter
BusAdapter (PROFINET)Yes; BA 2x RJ45, BA 2x FC, BA 2x M12, BA 2x SCRJ, BA SCRJ/RJ45, BA
PROFINET IO deviceYes
PROFINET IOYes
PROFIsafeYes
PROFINET system redundancy (S2)Yes; NAP S2
between PROFINET and all other circuitsYes; 1500 V AC (type test)
PROFINET Security Class1
Condiciones ambientales
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Otras características
Product type designationIM 155-6 PN/2 HF
HW functional statusFrom FS02
Firmware versionV4.2
FW update possibleYes
I&M dataYes; I&M0 to I&M3
Module swapping during operation (hot swapping)Yes; Multi-hot swapping
Isochronous modeYes
Tool changerYes; Docking station and docking unit
STEP 7 TIA Portal configurable/integrated from versionV15.1
STEP 7 configurable/integrated from versionuse GSD file
via datasetYes
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Short-circuit protectionYes
Mains/voltage failure stored energy time10 ms
Current consumption, max.700 mA
Inrush current, max.4.5 A
I²t0.25 A²·s
Power loss, typ.2.4 W
Address space per module, max.288 byte; For input and output data respectively
Address space per station, max.1 440 byte
Quantity of operable ET 200SP modules, max.64
Quantity of operable ET 200AL modules, max.16
Number of submodules per station, max.256
Transmission procedure100BASE-TX
Number of ports2; with BusAdapter
integrated switchYes
Open IE communicationYes
Media redundancyYes; PROFINET MRP client
IRTYes; 250 µs to 4 ms in 125 µs frame
PROFIenergyYes
Prioritized startupYes
Shared deviceYes
Number of IO Controllers with shared device, max.4
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Number of MtM communication16
H-Sync forwardingYes
MRPYes
TCP/IPYes
SNMPYes
LLDPYes
EquidistanceYes
shortest clock pulse250 µs
max. cycle4 ms
Bus cycle time (TDP), min.250 µs
Jitter, max.1 µs
Status indicatorYes
AlarmsYes
Diagnostics functionYes
RUN LEDYes; green LED
ERROR LEDYes; red LED
MAINT LEDYes; Yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapter
between different circuitsSafety extra low voltage SELV
Isolation tested with707 V DC (type test)
Network loading class3
horizontal installation, min.-30 °C; No condensation
horizontal installation, max.60 °C
vertical installation, min.-30 °C; No condensation
vertical installation, max.50 °C
dew point, min.-60 °C; suitable for dry room applications
via BU/BA SendYes; + 16 ET 200AL modules
Strain reliefYes; Optional
Width50 mm
Height117 mm
Depth74 mm
Weight, approx.120 g; without BusAdapter
IDEA4
UNSPSC15
For use in hazardous locationsMaritime application
NK / Nippon Kaiji KyCCS (China Classifica-
okaition Society)
last modified:5/20/2026
⬇ Descargar datasheet (PDF)

Ficha técnica oficial del fabricante con todas las especificaciones.

Material con posibilidad de devolución
ET 200SP, IM155-6PN/2 HF
€406,21 EUR
€477,90 EUR
6ES7155-6AU01-0CN0
Plazo de entrega (días):
€406,21 EUR /cada
Total:

Accesorios