Especificaciones técnicas
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Isolation tested with | 2 500 V DC (type test) |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
Datos eléctricos
| Current consumption (rated value) | 55 mA; without load |
|---|---|
| Power loss, typ. | 1.5 W |
| Current-sinking | Yes |
| Current-sourcing | Yes |
| Current per channel, max. | 5 A; > +60 °C max. continuous current per relay 3 A |
| Current per module, max. | 20 A |
| Rated supply voltage of relay coil L+ (DC) | 24 V |
| Current consumption of relays (coil current of all relays), | 40 mA |
| Thermal continuous current, max. | 5 A; Max. 1 385 VA, 150 W |
| Switching current, min. | 100 mA; 5 V DC |
| Rated switching voltage (DC) | 24 V DC to 120 V DC |
| Rated switching voltage (AC) | 24V AC to 230V AC |
| Monitoring the supply voltage | Yes |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| between the channels and the power supply of the | Yes |
| between channels and backplane bus/supply voltage | 240 V AC |
| between backplane bus and supply voltage | 707 V DC (type test) |
Condiciones ambientales
| Installation altitude above sea level, max. | 3 000 m |
|---|
Otras características
| Product type designation | RQ 4x120 VDC ... 230 VAC/5 A NO ST |
|---|---|
| based on | 6ES7132-6HD01-0BB1 |
| usable BaseUnits | BU type B0, B1 |
| I&M data | Yes; I&M0 to I&M3 |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Redundancy capability | Yes |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Rated value (AC) | 230 V |
| Inputs | + 1 byte for QI information |
| Outputs | 1 byte |
| Automatic encoding | Yes |
| Mechanical coding element | Yes |
| Type of mechanical coding element | type C |
| 2-wire connection | BU type B1 |
| 3-wire connection | BU type B0 |
| Type of digital output | Relays |
| Number of digital outputs | 4 |
| Digital outputs, parameterizable | Yes |
| for logic links | Yes |
| for redundant control of a load | Yes |
| up to 50 °C, max. | 20 A |
| up to 60 °C, max. | 16 A |
| up to 40 °C, max. | 20 A |
| Number of relay outputs | 4 |
| Number of operating cycles, max. | 7 000 000; see additional description in the manual |
| shielded, max. | 1 000 m |
| unshielded, max. | 200 m |
| Diagnostics function | Yes |
| Substitute values connectable | Yes |
| Diagnostic alarm | Yes |
| Channel status display | Yes; green LED |
| for module diagnostics | Yes; green/red DIAG LED |
| between the channels | Yes |
| between the channels and backplane bus | Yes |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| vertical installation, min. | -40 °C; in all other mounting positions |
| vertical installation, max. | 50 °C; in all other mounting positions |
| 2-38, max. | condensation conditions) |
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
| 60721-3-3 | Class 3B3 on request |
| to EN 60721-3-3 | 0AA0) |
| 60721-3-6 | request |
| to EN 60721-3-6 | 0AA0) |
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 40 g |
| EMV | Maritime application |
| last modified: | 10/23/2025 |