Arrancador suave SIRIUS, 32A, resorte
Certificados y homologaciones
CECSAATEX / ExIECEx
Siemens

Arrancador suave SIRIUS, 32A, resorte

Arrancadores suaves SIRIUS 200-480 V 32 A, 24 V AC/DC bornes de resorte de seguridad

  • Comunicación3RW5980-0CS00
Protección y seguridad
intrinsic device protectionYes
evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
type of the motor protectionElectronic, tripping in the event of thermal overload of the motor
design of the overvoltage protectionVaristor
performance level (PL) according to ISO 13849-1PL c
category according to ISO 13849-12
according to IEC 61508SIL 1
safety device type according to IEC 61508-2Type B
PFHD with high demand rate according to IEC 615081E-6 1/h
PFDavg with low demand rate according to IEC 615080.09
hardware fault tolerance according to IEC 615080
T1 value of service life according to IEC 6150820 a
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Safety Integrity Level (SIL) according to IEC 61508 relatingSIL 1
hardware fault tolerance according to IEC 61508 relating to0
Datos eléctricos
starting voltage [%]20 ... 100 %
stopping voltage [%]50 %; non-adjustable
current limiting value [%] adjustable125 ... 800 %
breakaway voltage [%] adjustable40 ... 100 %
current unbalance limiting value [%]10 ... 60 %
for main current circuit100 ms
insulation voltage rated value480 V
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 600 V
surge voltage resistance rated value6 kV
adjustable current limitationYes
voltage rampYes
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at-15 %
relative positive tolerance of the operating voltage at10 %
type of voltage of the control supply voltageAC/DC
relative negative tolerance of the control supply voltage at-20 %
relative positive tolerance of the control supply voltage at20 %
control supply voltage frequency50 ... 60 Hz
relative negative tolerance of the control supply voltage-10 %
relative positive tolerance of the control supply voltage10 %
control supply voltage at DC rated value24 V
control supply current in standby mode rated value420 mA
holding current in bypass operation rated value820 mA
inrush current by closing the bypass contacts maximum0.91 A
inrush current peak at application of control supply voltage7.5 A
duration of inrush current peak at application of control supply20 ms
for AWG cables for main current circuit solid2x (16 ... 12), 2x (14 ... 8)
Entradas/Salidas y comunicación
PROFINET standardYes
PROFINET high-featureYes
EtherNet/IPYes
Modbus RTUYes
Modbus TCPYes
PROFIBUSYes
Conexión y cableado
spring-loaded terminalYes
removable terminal for control circuitYes
for AWG cables for control circuit solid2x (24 ... 16)
for AWG cables for control circuit finely stranded with2x (24 ... 16)
for main contacts with screw-type terminals2 ... 2.5 N·m
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
Prestaciones y durabilidad
B10d value1 588 000
Certificados y homologaciones
UL approvalYes
CSA approvalYes
ATEXYes
IECExYes
according to ATEX directive 2014/34/EUBVS 18 ATEX F 003 X
Otras características
product brand nameSIRIUS
product categoryHybrid switching devices
product type designation3RW55
start-up ramp time of soft starter0 ... 360 s
ramp-down time of soft starter0 ... 360 s
start torque [%]10 ... 100 %
stopping torque [%]10 ... 100 %
torque limitation [%]20 ... 200 %
breakaway time adjustable0 ... 2 s
number of parameter sets3
accuracy class5 (based on IEC 61557-12)
CE markingYes
HMI-High FeatureYes
is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases3
ground-fault monitoring limiting value [%]10 ... 95 %
for control circuit100 ms
idle time adjustable0 ... 255 s
degree of pollution3, acc. to IEC 60947-4-2
service factor1.15
between main and auxiliary circuit480 V; does not apply for thermistor connection
shock resistance15 g / 11 ms, from 6 g / 11 ms with potential contact lifting
vibration resistance15 mm up to 6 Hz; 2 g up to 500 Hz
recovery time after overload trip adjustable60 ... 1 800 s
utilization category according to IEC 60947-4-2AC 53a
Net Weight3.168 kg
ramp-up (soft starting)Yes
soft stoppingYes
breakaway pulseYes
creep speed in both directions of rotationYes
pump stopYes
DC brakingYes
motor heatingYes
min/max pointerYes
trace functionYes
inside-delta circuitYes
auto-RESETYes
manual RESETYes
remote resetYes
communication functionYes
operating measured value displayYes
event listYes
error logbookYes
via software parameterizableYes
via software configurableYes
firmware updateYes
torque controlYes
combined brakingYes
analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
programmable control inputs/outputsYes
condition monitoringYes
automatic parameterisationYes
application wizardsYes
alternative stopping modeYes
emergency operation modeYes
reversing operationYes
soft starting at heavy starting conditionsYes
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
minimum load [%]10 %; Relative to set Ie
number of digital inputs4
parameterizable4
number of digital outputs3
Number of digital outputs with fail-safe1
number of digital outputs parameterizable2
number of digital outputs not parameterizable1
number of analog outputs1
fastening methodscrew fixing
height275 mm
width170 mm
depth152 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
solid2x (1.0 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
finely stranded with core end processing2x (1.0 ... 2.5 mm²), 2x (2.5 ... 6.0 mm²)
for control circuit solid2x (0.25 ... 1.5 mm²)
between soft starter and motor maximum800 m
for auxiliary and control contacts with screw-type0.8 ... 1.2 N·m
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
usable for Standard Faults up to 575/600 VType: Class RK5 / K5, max. 125 A; Iq = 5 kA
usable for High Faults up to 575/600 V according toType: Class J / L, max. 125 A; Iq = 100 kA
usable for Standard Faults at inside-delta circuit upType: Class RK5 / K5, max. 125 A; Iq = 5 kA
usable for High Faults at inside-delta circuit up toType: Class J / L, max. 125 A; Iq = 100 kA
contact rating of auxiliary contacts according to ULR300-B300
product function suitable for safety functionYes
safety-related switching OFFYes
safe stateOpen load circuit
function test interval maximum1a
stop category according to IEC 60204-10
average diagnostic coverage level (DCavg)90 %
MTTFd39 a
Safety Integrity Level (SIL) according to IEC 62061SIL 1
PFHD with high demand rate according to IEC 620611E-6 1/h
Safe failure fraction (SFF)60 %
tificateates/Test Report
1/L13/L2
5/L3A1
13 NO23 NO
F-DIL+
DI 2DI 3
AQ I+AQ U+
98 NO96 NC
last modified:9/5/2025

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito.

Plazo de entrega (días):
Avísame cuando haya stock

Si prefieres esperar a que vuelva a haber envío inmediato, déjanos tu email.

Solo usaremos tu email para avisarte de este artículo.

Avísame cuando esté disponible

Arrancador suave SIRIUS, 32A, resorte
€2.178,93 EUR + IVA
3RW5516-3HF04
Plazo de entrega (días):
€2.178,93 EUR /cada
Total:

Accesorios