Relé vigilancia, 3UG, pérdida de fase, 2CO, 690V AC, resorte
Siemens

Relé vigilancia, 3UG, pérdida de fase, 2CO, 690V AC, resorte

Variante con ajuste digital de relé de vigilancia vigilancia de pérdida de fase, de secuencia de fases, de asimetría, de frecuencia, de sobretensión y vigilancia de subtensión, con/sin conductor neutro con corrección de secuencia de fases 3x 90-690 V AC, 15-70 Hz 2 conmutados borne de resorte

Medición y rango
relative metering precision3%
Conexión y cableado
operating frequency with 3RT2 contactor maximum5 000 1/h
product component removable terminal for main circuitYes
product component removable terminal for auxiliary andYes
for AWG cables solid1x (20 ... 12)
for AWG cables stranded20 ... 12
Montaje y material
material of switching contactsAgSnO2
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
Otras características
product brand nameSIRIUS
product type designation3UG5
product functionline monitoring
design of the displayLCD
power loss [W] maximum2W
power loss [V·A] maximum5.1 VA
with degree of pollution 2 rated value690 V
with degree of pollution 3 rated value690 V
degree of pollution3
for monitoringAC
of the operating voltage for actuationAC/DC
surge voltage resistance rated value6 kV
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15 g / 11 ms
vibration resistance according to IEC 60068-2-610 ... 55 Hz: 0.35 mm
switching behaviormonostable
mechanical service life (operating cycles) typical10 000 000
thermal current of the switching element with contacts5A
adjustable OFF-delay time0.1 ... 30 s
relative repeat accuracy0%
Net Weight0.167 kg
undervoltage detectionYes
overvoltage detectionYes
phase sequence recognitionYes
phase failure detectionYes
asymmetry detectionYes
overvoltage detection 3 phaseYes
undervoltage detection 3 phasesYes
voltage window recognition 3 phaseYes
adjustable open/closed-circuit current principleYes
auto-RESETYes
neutral conductor monitoring adjustableYes
type of voltage of the control supply voltageAC
at 50 Hz200 ... 690 V
at 60 Hz200 ... 690 V
initial value0.85
full-scale value1.1
supply voltage frequency rated value70 ... 15 Hz
measurable voltage 1 at AC160 ... 760 V
measurable voltage 2 at AC90 ... 440 V
adjustable operating delay time initial value0s
when starting0.1 ... 999.8 s
with lower or upper limit violation0.1 ... 999.8 s
buffering time in the event of power failure minimum20 ms
response time maximum500 ms
accuracy of digital display+/-1 digit
relative temperature-related measurement deviation1%
temperature drift per °C0 %/°C
number of NC contacts delayed switching0
number of NO contacts delayed switching0
for auxiliary contacts2
delayed switching2
contact rating of auxiliary contacts according to ULR300 / B300
number of poles for main current circuit4
at 250 V at 50/60 Hz3A
at 24 V1A
at 110 V0.2 A
at 125 V0.2 A
at 230 V0.1 A
at 250 V0.1 A
operational current at 17 V minimum5 mA
EMC emitted interference according to IEC 60947-1class A
due to burst according to IEC 61000-4-42 kV (power ports), 2 kV (signal ports)
due to conductor-earth surge according to IEC 61000-4-52 kV
due to conductor-conductor surge according to IEC1 kV
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
design of the electrical isolationgalvanic isolation
between input and outputYes
between the outputsYes
between the voltage supply and other circuitsYes
protection class IP on the front according to IEC 60529IP20
type of electrical connectionspring-loaded terminal (push-in)
solid1x (0.5 ... 4 mm²)
finely stranded with core end processing1x (0.5 ... 2.5 mm²)
finely stranded without core end processing0.5 ... 4 mm²
stranded20 ... 12
stripped length10 mm
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm DIN rail
height100 mm
width22.5 mm
depth90 mm
forwards0 mm
backwards0 mm
upwards0 mm
downwards0 mm
at the side0 mm
during operation-25 ... +60 °C
during storage-40 ... +85 °C
during transport-40 ... +85 °C
relative humidity during operation maximum70 %
last modified:6/30/2026
⬇ Descargar datasheet (PDF)

Ficha técnica oficial del fabricante con todas las especificaciones.

Devolución limitada, consultar condiciones
Relé vigilancia, 3UG, pérdida de fase, 2CO, 690V AC, resorte
€225,04 EUR
€608,22 EUR
3UG5618-2CR20
Plazo de entrega (días):
€225,04 EUR /cada
Total:

Accesorios