Especificaciones técnicas
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Short-circuit protection | Yes; Per module, 5x 20 mm fuse, 2 A/250 V, quick-response, replaceable |
| Isolation tested with | 1 200 V DC between supply voltage and backplane bus |
Datos eléctricos
| Current consumption, max. | 70 mA; without sensor supply |
|---|---|
| Power loss, typ. | 1.5 W |
| Monitoring the supply voltage | Yes |
| Monitoring of encoder power supply | Yes |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Entradas/Salidas y comunicación
| suitable for operation on PROFINET R1 IMs | Yes |
|---|---|
| PROFIBUS from GSD version/GSD revision | One GSD file each, Revision 3 and 5 and higher |
| PROFINET from GSD version/GSD revision | GSDML V2.3 |
Detección y sensórica
| 2-wire sensor | Yes |
|---|
Condiciones ambientales
| Installation altitude above sea level, max. | 2 000 m; On request: Installation altitudes greater than 2 000 m |
|---|
Otras características
| Product type designation | DI 8x24VAC/48VUC BA |
|---|---|
| HW functional status | From FS02 |
| Firmware version | V0.0 |
| usable BaseUnits | BU type U0 |
| I&M data | Yes; I&M0 to I&M3 |
| STEP 7 TIA Portal configurable/integrated from version | V15 |
| STEP 7 configurable/integrated from version | V5.6 |
| Rated value (DC) | 48 V |
| permissible range, lower limit (DC) | 40.8 V |
| permissible range, upper limit (DC) | 57.6 V |
| Rated value (AC) | 48 V; 24 V/48 V; 50 Hz/60 Hz |
| permissible range, lower limit (AC) | 40.8 V |
| permissible range, upper limit (AC) | 52.8 V |
| Number of outputs | 8 |
| up to 60 °C, max. | 1A |
| Address space per module, max. | 1 byte |
| Mechanical coding element | Yes |
| Type of mechanical coding element | type C |
| 1-wire connection | BU type U0 |
| 2-wire connection | BU type U0 |
| 3-wire connection | BU type U0 + Potential distributor module |
| 4-wire connection | BU type U0 + Potential distributor module |
| Number of digital inputs | 8 |
| Sourcing/sinking input | P-reading |
| for signal "0" | AC/DC < 10 V |
| for signal "1" | AC > 14 V, DC > 34 V |
| for signal "1", typ. | 3.5 mA |
| shielded, max. | 1 000 m |
| unshielded, max. | 600 m |
| Diagnostics function | Yes |
| Diagnostic alarm | Yes |
| Diagnostic information readable | Yes |
| Group error | Yes |
| Channel status display | Yes; green LED |
| for module diagnostics | Yes; green/red DIAG LED |
| between the channels and backplane bus | Yes |
| horizontal installation, min. | -30 °C |
| horizontal installation, max. | 60 °C |
| vertical installation, min. | -30 °C |
| vertical installation, max. | 50 °C |
| dew point, min. | -60 °C; suitable for dry room applications |
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 40 g |
| last modified: | 2/1/2026 |