Contactor condensador, 75kVAr, 110V AC, tam. S3, tornillo
Siemens

Contactor condensador, 75kVAr, 110V AC, tam. S3, tornillo

Contactor para condensador, AC-6b 75 kVAr, /400 V, tripolar, 110 V AC, 50 Hz, contactos auxiliares: 1 NA + 1 NC, borne de tornillo, tamaño: S3

Datos eléctricos
product extension auxiliary switchYes
Conexión y cableado
size of contactorS3
of the contactor with added auxiliary switch block typical3 000 000
at contactor for auxiliary contactsScrew-type terminals
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
AWG number as coded connectable conductor cross8
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
operational current at AC-6b at 690 V at ambient temperature108 A
at 230 V at 50/60 Hz at ambient temperature 60 °C rated14 ... 43 kvar
at 400 V at 50/60 Hz at ambient temperature 60 °C rated25 ... 75 kvar
at 500 V at 50/60 Hz at ambient temperature 60 °C rated31 ... 94 kvar
at 690 V at 50/60 Hz at ambient temperature 60 °C rated43 ... 129 kvar
Otras características
product brand nameSIRIUS
product type designation3RT26
at AC in hot operating state per pole5.3 W
without load current share typical7.3 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value1 000 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
at AC10.3 g / 5 ms, 6,7 g / 10 ms
electrical endurance (operating cycles)200 000
Net Weight1.787 kg
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-3095 %
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at 230 V maximum200 1/h
at 240 V maximum200 1/h
at 400 V maximum100 1/h
at 480 V maximum60 1/h
at 500 V maximum60 1/h
at 600 V maximum40 1/h
at 690 V maximum40 1/h
type of voltageAC
type of voltage of the control supply voltageAC
at 50 Hz rated value110 V
1 rated value50 Hz
at 50 Hz0.8 ... 1.1
apparent pick-up power of magnet coil at AC296 VA
inductive power factor with closing power of the coil0.61
apparent holding power of magnet coil at AC19 VA
arcing time10 ... 20 ms
control version of the switch operating mechanismStandard A1 - A2
number of NC contacts for auxiliary contacts1
attachable1
instantaneous contact1
number of NO contacts for auxiliary contacts1
at 230 V6A
at 400 V3A
at 690 V0A
at 24 V6A
at 60 V2A
at 110 V1A
at 125 V0.9 A
at 220 V0.3 A
contact reliability of auxiliary contacts0.00000001
contact rating of auxiliary contacts according to ULA600 / Q600
height140 mm
width80 mm
depth152 mm
with side-by-side mounting at the side10 mm
for grounded parts at the side10 mm
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
of magnet coilScrew-type terminals
solid2x (10 ... 16 mm²)
stranded2x (10 ... 70 mm²), 1x (10 ... 70 mm²)
solid or stranded2x (10 ... 70 mm²), 1x (10 ... 70 mm²)
finely stranded with core end processing2x (10 ... 50 mm²)
at 40 °C1x 50 mm²
at 60 °C2x 35 mm²
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
3/L25/L3
last modified:4/4/2026
⬇ Descargar datasheet (PDF)

Ficha técnica oficial del fabricante con todas las especificaciones.

Material con posibilidad de devolución
Contactor condensador, 75kVAr, 110V AC, tam. S3, tornillo
€366,15 EUR
€989,59 EUR
3RT2645-1AF03
Plazo de entrega (días):
€366,15 EUR /cada
Total:

Accesorios