Arrancador suave SIRIUS, 470A, 24V, tornillo
Siemens

Arrancador suave SIRIUS, 470A, 24V, tornillo

Arrancadores suaves SIRIUS 200-600 V 470 A, AC/DC 24 V bornes de tornillo salida de termistor

🔌 Comunicación3RW5980-0CS00
Protección y seguridad
Safety Integrity Level (SIL) according to IEC 61508 relatingSIL 1
PFHD with high demand rate according to IEC 615089E-6 1/h
PFDavg with low demand rate according to IEC 615080.09
hardware fault tolerance according to IEC 61508 relating to0
Entradas/Salidas y comunicación
of communication module PROFINET standard usable3RW5980-0CS00
of communication module PROFIBUS usable3RW5980-0CP00
of communication module Modbus TCP usable3RW5980-0CT00
of communication module Modbus RTU usable3RW5980-0CR00
of communication module Ethernet/IP3RW5980-0CE00
PROFINET standardYes
EtherNet/IPYes
Modbus RTUYes
Modbus TCPYes
PROFIBUSYes
Conexión y cableado
of line contactor usable up to 480 V3RT1076
of line contactor usable up to 690 V3RT1076
r box terminal using the back clamping point250 ... 500 kcmil
for AWG cables for main current circuit solid2/0 ... 500 kcmil
for DIN cable lug for main contacts stranded50 ... 240 mm²
for DIN cable lug for main contacts finely stranded70 ... 240 mm²
for AWG cables for control circuit solid1x (20 ... 12), 2x (20 ... 14)
for main contacts with screw-type terminals14 ... 24 N·m
Condiciones ambientales
installation altitude at height above sea level maximum5 000 m
Certificados y homologaciones
ATEXYes
Otras características
product brand nameSIRIUS
product categoryHybrid switching devices
product type designation3RW50
of standard HMI module usable3RW5980-0HS01
of high feature HMI module usable3RW5980-0HF00
of circuit breaker usable at 400 V3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA
of circuit breaker usable at 500 V3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA
of the gG fuse usable up to 690 V2x3NA3365-6; Type of coordination 1, Iq = 65 kA
of full range R fuse link for semiconductor protection3NE1 436-2; Type of coordination 2, Iq = 65 kA
of back-up R fuse link for semiconductor protection3NE3 340-8; Type of coordination 2, Iq = 65 kA
starting voltage [%]30 ... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0 ... 20 s
ramp-down time of soft starter0 ... 20 s
current limiting value [%] adjustable130 ... 700 %
CE markingYes
UL approvalYes
CSA approvalYes
is supported HMI-StandardYes
is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases2
for main current circuit100 ms
for control circuit100 ms
insulation voltage rated value600 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 600 V
service factor1
surge voltage resistance rated value6 kV
between main and auxiliary circuit600 V
shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance15 mm to 6 Hz; 2 g to 500 Hz
utilization category according to IEC 60947-4-2AC-53a
Net Weight8.3 kg
ramp-up (soft starting)Yes
soft stoppingYes
Soft TorqueYes
adjustable current limitationYes
pump stopYes
intrinsic device protectionYes
evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
auto-RESETYes
manual RESETYes
remote resetYes; By turning off the control supply voltage
communication functionYes
operating measured value displayYes; Only in conjunction with special accessories
error logbookYes; Only in conjunction with special accessories
via software configurableYes
PROFIenergyYes; in connection with the PROFINET Standard communication module
voltage rampYes
at 40 °C rated value470 A
at 50 °C rated value416 A
at 60 °C rated value380 A
rated value200 ... 600 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
at 230 V at 40 °C rated value132 kW
at 400 V at 40 °C rated value250 kW
at 500 V at 40 °C rated value315 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
at rotary coding switch on switch position 1200 A
at rotary coding switch on switch position 2218 A
at rotary coding switch on switch position 3236 A
at rotary coding switch on switch position 4254 A
at rotary coding switch on switch position 5272 A
at rotary coding switch on switch position 6290 A
at rotary coding switch on switch position 7308 A
at rotary coding switch on switch position 8326 A
at rotary coding switch on switch position 9344 A
at rotary coding switch on switch position 10362 A
at rotary coding switch on switch position 11380 A
at rotary coding switch on switch position 12398 A
at rotary coding switch on switch position 13416 A
at rotary coding switch on switch position 14434 A
at rotary coding switch on switch position 15452 A
at rotary coding switch on switch position 16470 A
minimum200 A
minimum load [%]15 %; Relative to smallest settable Ie
at 40 °C after startup56 W
at 50 °C after startup44 W
at 60 °C after startup37 W
at 40 °C during startup5 344 W
at 50 °C during startup4 438 W
at 60 °C during startup3 876 W
type of the motor protectionElectronic, tripping in the event of thermal overload of the motor
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value24 V
at 60 Hz rated value24 V
control supply voltage frequency50 ... 60 Hz
control supply voltage at DC rated value24 V
control supply current in standby mode rated value160 mA
holding current in bypass operation rated value490 mA
inrush current by closing the bypass contacts maximum7.6 A
design of the overvoltage protectionVaristor
number of digital inputs1
number of digital outputs3
not parameterizable2
digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs0
at AC-15 at 250 V rated value3A
at DC-13 at 24 V rated value1A
fastening methodscrew fixing
height230 mm
width160 mm
depth282 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
width of connection bar maximum35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
using the front clamping point solid95 ... 300 mm²
using the front clamping point stranded95 ... 300 mm²
using the back clamping point solid120 ... 240 mm²
using both clamping points solidmin. 2x 70 mm², max. 2x 240 mm²
using both clamping points finely stranded without coremin. 2x 50 mm², max. 2x 185 mm²
using both clamping points strandedmin. 2x 70 mm², max. 2x 240 mm²
using the back clamping point finely stranded with core120 ... 185 mm²
using the back clamping point stranded120 ... 240 mm²
for control circuit solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
between soft starter and motor maximum800 m
at the digital inputs at AC maximum1 000 m
for auxiliary and control contacts with screw-type0.8 ... 1.2 N·m
during storage and transport-40 ... +80 °C
during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
usable for Standard Faults up to 575/600 VType: Class L, max. 1600 A; Iq = 30 kA
usable for High Faults up to 575/600 V according toType: Class L, max. 1200 A; Iq = 100 kA
at 200/208 V at 50 °C rated value150 hp
at 220/230 V at 50 °C rated value150 hp
at 460/480 V at 50 °C rated value350 hp
at 575/600 V at 50 °C rated value450 hp
protection class IP on the front according to IEC 60529IP00; IP20 with cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
IECExYes
UKEXYes
1/L13/L2
5/L3A1
ON/RUNBYPASSED
13 NO23 NO
98 NO96 NC
last modified:4/4/2026
⬇ Descargar datasheet (PDF)

Ficha técnica oficial del fabricante con todas las especificaciones.

Material con posibilidad de devolución
Arrancador suave SIRIUS, 470A, 24V, tornillo
€4.142,13 EUR
€6.372,51 EUR
3RW5076-6TB05
Plazo de entrega (días):
€4.142,13 EUR /cada
Total:

Accesorios