Arrancador directo 3RM1, 7A, 24V DC, resorte

Arrancador directo 3RM1, 7A, 24V DC, resorte

Especificaciones
Arrancador directo, 3RM1, 500 V, 0,55 - 3 kW, 1,6 - 7 A, 24 V DC, borne de tornillo/resorte (inserción directa)

  • Potencia (kW)3.0

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito.

Plazo de entrega (días):
Avísame cuando haya stock

Si prefieres esperar a que vuelva a haber envío inmediato, déjanos tu email.

Solo usaremos tu email para avisarte de este artículo.

Avísame cuando esté disponible

Arrancador directo 3RM1, 7A, 24V DC, resorte
€265,21 EUR + IVA
€530,42 EUR
3RM1007-3AA04
Plazo de entrega (días):
€265,21 EUR /cada
Total:

Especificaciones técnicas

Protección y seguridad
intrinsic device protectionYes
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe
type of the motor protectionsolid-state
Datos eléctricos
without load current share typical1.68 W
insulation voltage rated value500 V
overvoltage categoryIII
surge voltage resistance rated value6 kV
number of poles for main current circuit3
adjustable current response value current of the current1.6 ... 7 A
operating voltage rated value48 ... 500 V
relative symmetrical tolerance of the operating voltage10 %
operating power for 3-phase motors at 400 V at 50 Hz0.55 ... 3 kW
input voltage at digital input at DC rated value24 V
operational current of auxiliary contacts at AC-15 at 230 V3A
operational current of auxiliary contacts at DC-13 at 24 V1A
type of voltage of the control supply voltageDC
control supply voltage at DC rated value19.2 ... 30 V
relative negative tolerance of the control supply voltage at20 %
relative positive tolerance of the control supply voltage at25 %
control supply voltage 1 at DC rated value24 V
for main current circuitscrew-type terminals
operational current at AC at 480 V according to UL 5086.1 A
Conexión y cableado
for AWG cables for auxiliary contacts1x (20 ... 16), 2x (20 ... 16)
AWG number as coded connectable conductor cross20 ... 12
Condiciones ambientales
vibration resistance1 ... 6 Hz, 15 mm; 20 m/s², 500 Hz
installation altitude at height above sea level maximum4 000 m
Otras características
product brand nameSIRIUS
product categoryMotor starter
design of the productwith electronic overload protection
product type designation3RM1
equipment version according to IEC 60947-4-23
product functionDirect-on-line starter
suitability for operation device connector 3ZY12Yes
between main and auxiliary circuit500 V
between control and auxiliary circuit250 V
shock resistance6 g / 11 ms
operating frequency maximum1 1/s
Net Weight0.292 kg
direct startYes
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1Class A
due to burst according to IEC 61000-4-43 kV / 5 kHz
due to conductor-earth surge according to IEC 61000-4-52 kV
due to conductor-conductor surge according to IEC1 kV
due to high-frequency radiation according to IEC 6100010 V
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
conducted HF interference emissions according toClass B for the domestic, business and commercial environments
design of the switching contactHybrid
minimum load [%]20 %; from set rated current
operating frequency 1 rated value50 Hz
operating frequency 2 rated value60 Hz
ampacity when starting maximum56 A
derating temperature40 °C
for signal <1> at DC11 mA
number of CO contacts for auxiliary contacts1
initial value0.8
full-scale value1.25
ON-delay time60 ... 90 ms
OFF-delay time60 ... 90 ms
mounting positionvertical, horizontal, standing (observe derating)
fastening methodscrew and snap-on mounting onto 35 mm DIN rail
height100 mm
width22.5 mm
depth141.5 mm
forwards0 mm
backwards0 mm
upwards50 mm
downwards50 mm
60721(sand must not get into the devices), 3M6
relative humidity during operation10 ... 95 %
air pressure according to SN 31205900 ... 1 060 hPa
for auxiliary and control circuitspring-loaded terminals (push-in)
wire length for motor unshielded maximum100 m
solid1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
finely stranded with core end processing1x (0,5 ... 4 mm²), 2x (0,5 ... 1,5 mm²)
solid or stranded0.5 ... 4 mm²
finely stranded without core end processing0.5 ... 1.5 mm²
EMVother
1/L13/L2
5/L3A1
IN1Start
IN3Reset
6/T3OUT
Run96
last modified:4/23/2026