ET 200SP, IM155-6PN ST incl. BA 2xRJ45

Producto descatalogado No disponible para compra · sin producto de reemplazo.
SIMATIC ET 200SP, Bundle PROFINET IM, IM 155-6PN ST, máx. 32 módulos de periferia y 16 módulos ET 200AL, Single Hot Swapping, Bundle compuesto por: Módulo de interfaz (6ES7155-6AU01-0BN0), Módulo de servidor (6ES7193-6PA00-0AA0), Adaptador de bus BA 2xRJ45 (6ES7193-6AR00-0AA0)

🔌 ComunicaciónGSDML V2.35
Entradas/Salidas y comunicación
PROFINET from GSD version/GSD revisionGSDML V2.35
Number of PROFINET interfaces1; 2 ports (switch)
RJ 45 (Ethernet)Yes; with BusAdapter
BusAdapter (PROFINET)Yes; BA 2x RJ45, BA 2x FC, BA 2x M12
PROFINET IO DeviceYes
Supports protocol for PROFINET IOYes
PROFIsafeYes
between PROFINET and all other circuitsYes; 1500 V AC (type test)
PROFINET Security Class1
Condiciones ambientales
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Otras características
Product type designationIM155-6PN ST, including BusAdapter BA 2x RJ45
HW functional statusFrom FS03
Firmware versionV4.2
FW update possibleYes
I&M dataYes; I&M0 to I&M3
Module swapping during operation (hot swapping)Yes; Single hot swapping
STEP 7 TIA Portal configurable/integrated from versionV14
STEP 7 configurable/integrated from versionV5.5 SP4
via datasetYes
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Short-circuit protectionYes
Mains/voltage failure stored energy time10 ms
Current consumption (rated value)450 mA
Current consumption, max.550 mA
Inrush current, max.3.7 A
I²t0.09 A²·s
Power loss, typ.1.9 W
Address space per module, max.256 byte; For input and output data respectively
Address space per station, max.512 byte
Quantity of operable ET 200SP modules, max.32
Quantity of operable ET 200AL modules, max.16
Number of submodules per station, max.256
Transmission procedure100BASE-TX
Number of ports2; with BusAdapter
integrated switchYes
Open IE communicationYes
Media redundancyYes; PROFINET MRP client
IRTYes; 250 µs to 4 ms in 125 µs frame
PROFIenergyYes
Prioritized startupYes
Shared deviceYes
Number of IO Controllers with shared device, max.2
100 MbpsYes
AutonegotiationYes
AutocrossingYes
MRPYes
TCP/IPYes
SNMPYes
LLDPYes
Status indicatorYes
AlarmsYes
Diagnostics functionYes
RUN LEDYes; green LED
ERROR LEDYes; red LED
MAINT LEDYes; Yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapter
between different circuitsSafety extra low voltage SELV
Isolation tested with707 V DC (type test)
Network loading class3
horizontal installation, min.-30 °C; No condensation
horizontal installation, max.60 °C
vertical installation, min.-30 °C; No condensation
vertical installation, max.50 °C
via BU/BA SendYes; + 16 ET 200AL modules
Width50 mm
Height117 mm
Depth74 mm
Weight, approx.147 g; without BusAdapter