SIPLUS ET 200SP IM155-6PN ST
Siemens

SIPLUS ET 200SP IM155-6PN ST

Producto descatalogado No disponible para compra · sin producto de reemplazo.
SIPLUS ET 200SP IM155-6PN ST basado en 6ES7155-6AU01-0BN0 con revestimiento conformado, –40…+70 °C, módulo de interfaz PROFINET, 1 slot para BusAdapter, máx. 32 módulos de periferia, y 16 módulos ET 200AL, Single hot swap, módulo servidor incluido (6AG1193-6PA00-7AA0)

  • Comunicación1; 2 ports (switch)
Entradas/Salidas y comunicación
Number of PROFINET interfaces1; 2 ports (switch)
BusAdapter (PROFINET)Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC
PROFINET IO deviceYes
Supports protocol for PROFINET IOYes
PROFIsafeYes
between PROFINET and all other circuitsYes; 1 500 V AC
Condiciones ambientales
Installation altitude above sea level, max.5 000 m
Otras características
Product type designationIM 155-6 PN ST
Vendor identification (VendorID)002AH
Device identifier (DeviceID)0313H
based on6ES7155-6AU01-0BN0
I&M dataYes; I&M0 to I&M3
Module swapping during operation (hot swapping)Yes; Single hot swapping
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
via datasetYes
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Short-circuit protectionYes
Mains/voltage failure stored energy time10 ms
Current consumption (rated value)450 mA
Current consumption, max.550 mA
Inrush current, max.3.7 A
I²t0.09 A²·s
Infeed power to the backplane bus4.5 W
Power loss, typ.1.9 W
Address space per module, max.256 byte; per input / output
Address space per station, max.512 byte; Dependent on configuration
Modules per rack, max.32; + 16 ET 200AL modules
Number of submodules per station, max.256
Number of ports2
integrated switchYes
Open IE communicationYes
Media redundancyYes; PROFINET MRP
PROFIenergyYes
Prioritized startupYes
Shared deviceYes
Number of IO Controllers with shared device, max.2
Transmission procedurePROFINET with 100 Mbit/s full duplex (100BASE-TX)
10 MbpsYes; for Ethernet services
100 MbpsYes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)
AutonegotiationYes
AutocrossingYes
MRPYes
TCP/IPYes
SNMPYes
LLDPYes
Status indicatorYes
AlarmsYes
Diagnostics functionYes
RUN LEDYes; green LED
ERROR LEDYes; red LED
MAINT LEDYes; Yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapter
between different circuitsSafety extra low voltage SELV
Network loading class2
horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.70 °C; = Tmax
vertical installation, min.-40 °C; = Tmin
vertical installation, max.50 °C; = Tmax
2-38, max.horizontal installation
Resistant to commercially available coolants andYes; Incl. diesel and oil droplets in the air
60721-3-3Class 3B3 on request
to EN 60721-3-30AA0)
60721-3-6request
to EN 60721-3-60AA0)
conditions acc. to EN 60721, EN 60654-4 andduring operation!
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical InsulatingYes; Conformal coating, Class A
via BU/BA SendYes; + 16 ET 200AL modules
Width50 mm
Height117 mm
Depth74 mm
Weight, approx.147 g; without BusAdapter
IDEA4
UNSPSC15
EMVFor use in hazardous locations
last modified:10/9/2024

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito. Si prefieres esperar a que vuelva a haber stock inmediato, déjanos tu email abajo.

Plazo de entrega (días):

Este artículo va bajo pedido.

Avísame cuando esté disponible

Solo usaremos tu email para avisarte de este artículo.

Accesorios