ET 200SP, DI 8xNAMUR HF
Siemens

ET 200SP, DI 8xNAMUR HF

SIMATIC ET 200SP, módulo de entrada digital, DI 8x NAMUR High Feature, adecuado para tipo de BU A0, código de color CC01, diagnóstico de canal

🔌 ComunicaciónYes
Datos eléctricos
Pulse extensionYes; 0.5 s, 1 s, 2 s
Entradas/Salidas y comunicación
suitable for operation on PROFINET R1 IMsYes
PROFIBUS from GSD version/GSD revisionGSD Revision 5
PROFINET from GSD version/GSD revisionGSDML V2.42
Montaje y material
Color code for module-specific color-coded labelCC01
Condiciones ambientales
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Otras características
Product type designationDI 8xNAMUR HF
HW functional statusfrom FS21
Firmware versionV2.0 or higher
FW update possibleYes
usable BaseUnitsBU type A0
I&M dataYes; I&M0 to I&M3
STEP 7 TIA Portal configurable/integrated from versionV19
STEP 7 configurable/integrated from versionV5.5 SP3 / -
CounterYes
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Current consumption, max.70 mA
Number of outputs8
Short-circuit protectionYes
8.2 VYes
Output current per channel, max.8 mA
Output current per module, max.64 mA
Power loss, typ.1.5 W
Address space per module, max.1 byte
Outputs20 byte; 0 in DI mode; 20 bytes in Counter mode
Automatic encodingYes
Mechanical coding elementYes
Type of mechanical coding elementType A
Number of configurable submodules, max.1
2-wire connectionBU type A0
3-wire connectionBU type A0
Number of digital inputs8; NAMUR
Digital inputs, parameterizableYes
Sourcing/sinking inputP-reading
Edge evaluationYes; rising edge, falling edge, edge change
Signal change flutterYes; 2 to 32 signal changes
Flutter observation windowYes; 0.5 s, 1 s to 100 s in 1-s steps
Gate start/stopYes
Freely usable digital inputYes
Number, max.4; See manual for details
Counting frequency, max.5 kHz
Counting width32 bit
Counting direction up/downYes
for signal "0", min.0.35 mA
for signal "0", max.1.2 mA
for signal "1", min.2.1 mA
for signal "1", max.7 mA
for signal "0", max. (permissible quiescent current)0.5 mA
for signal "1", typ.8 mA
tolerated changeover time for changeover contacts300 ms
at "0" to "1", max.20 ms; See manual for details
at "1" to "0", max.20 ms; See manual for details
shielded, max.200 m; 50 m for Counter mode
NAMUR encoder/changeover contact according to ENYes
Single contact / changeover contact unconnectedYes
Single contact / changeover contact connected with 10Yes
Diagnostics functionYes
Diagnostic alarmYes; channel by channel
Hardware interruptYes; Parameterizable, channels 0 to 7
Diagnostic information readableYes
Monitoring the supply voltageYes
parameterizableYes
Wire breakYes; channel by channel
Short-circuitYes; channel by channel
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; green/red DIAG LED
between the channels and backplane busYes
Between the channels and load voltage L+Yes
between the channels and the power supply of theYes
Isolation tested with707 V DC (type test)
horizontal installation, min.-30 °C
horizontal installation, max.60 °C
vertical installation, min.-30 °C
vertical installation, max.50 °C
dew point, min.-60 °C; suitable for dry room applications
Width15 mm
Height73 mm
Depth58 mm
Weight, approx.32 g
IDEA4
UNSPSC15
For use in hazardous locationsMaritime application
NK / Nippon Kaiji KyCCS (China Classifica-
okaition Society)
last modified:2/1/2026
⬇ Descargar datasheet (PDF)

Ficha técnica oficial del fabricante con todas las especificaciones.

Material con posibilidad de devolución
ET 200SP, DI 8xNAMUR HF
€319,52 EUR
€375,91 EUR
6ES7131-6TF00-0CA0
Plazo de entrega (días):
€319,52 EUR /cada
Total:

Accesorios