Especificaciones técnicas
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Short-circuit protection | Yes; Electronic (response threshold 0.7 A to 2.1 A) |
| Overload protection | Yes |
| Isolation tested with | 750 V DC (type test) and according to EN 50155 (routine test) |
| Performance level according to ISO 13849-1 | PLe |
| SIL acc. to IEC 61508 | SIL 3 |
| Fire protection acc. to EN 45545-2 | Yes; For proof of conformity, see Service & Support |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
Seguridad funcional
| High demand/continuous mode: PFH in accordance | < 1.00E-08 1/h |
|---|
Datos eléctricos
| Current consumption (rated value) | 75 mA; without load |
|---|---|
| Current consumption, max. | 21 mA; From the backplane bus |
| Output current, max. | 600 mA; Total current of all encoders |
| Power consumption from the backplane bus | 70 mW |
| Power loss, typ. | 5W |
| Type of input voltage | DC |
| Limitation of inductive shutdown voltage to | max. 1.5 V |
| for signal "0" residual current, max. | 1.5 mA; PP-switching: max. 1.5 mA; PM-switching: max. 1 mA |
| Current per channel, max. | 8 A; note derating data in the manual |
| Current per module, max. | 8 A; note derating data in the manual |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Montaje y material
| Color code for module-specific color-coded label | CC52 |
|---|
Condiciones ambientales
| Installation altitude above sea level, max. | 2 000 m |
|---|---|
| Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
Certificados y homologaciones
| China RoHS | TUEV |
|---|
Otras características
| Product type designation | F-PM-E PPM 24VDC |
|---|---|
| based on | 6ES7136-6PA00-0BC0 |
| usable BaseUnits | BU type C0 |
| I&M data | Yes; I&M0 to I&M3 |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Number of outputs | 2 |
| up to 60 °C, max. | 0.3 A |
| 24 V | Yes; min. L+ (-1.5 V) |
| Inputs | 7 byte |
| Outputs | 5 byte |
| Automatic encoding | Yes |
| Electronic coding element type F | Yes |
| Number of digital inputs | 2 |
| Sourcing/sinking input | Yes; P-reading |
| for signal "0" | -30 to +5 V |
| for signal "1" | +15 to +30 V |
| for signal "1", typ. | 3.7 mA |
| parameterizable | Yes |
| shielded, max. | 1 000 m |
| unshielded, max. | 500 m |
| Number of digital outputs | 1 |
| Digital outputs, parameterizable | Yes |
| Response threshold, typ. | > 14.8 A |
| Open-circuit detection | Yes |
| lower limit | 3Ω |
| upper limit | 2 000 Ω |
| for signal "1", min. | 24 V; L+ (-0.5 V) |
| for signal "1" rated value | 8A |
| up to 40 °C, max. | 8 A; note derating data in the manual |
| up to 50 °C, max. | 6 A; note derating data in the manual |
| Diagnostics function | Yes; See Chapter "Alarms/diagnostic messages" in the manual |
| Diagnostic alarm | Yes |
| RUN LED | Yes; green LED |
| ERROR LED | Yes; red LED |
| Channel status display | Yes; green LED |
| for channel diagnostics | Yes; red LED |
| for module diagnostics | Yes; green/red DIAG LED |
| between the channels and backplane bus | Yes |
| Suitable for safety functions | Yes |
| 50716 | specific application under consideration of all local regulations. |
| Low demand mode: PFDavg in accordance with | < 2.00E-04 |
| EN 50121-3-2 | Yes; EMC for rail vehicles |
| EN 50121-4 | Yes; EMC for signal and telecommunications systems |
| EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
| EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
| EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; |
| EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
| horizontal installation, min. | -30 °C; = Tmin (incl. condensation/frost) |
| vertical installation, min. | -30 °C; = Tmin |
| vertical installation, max. | 50 °C; = Tmax |
| 2-38, max. | horizontal installation |
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
| 60721-3-3 | Class 3B3 on request |
| to EN 60721-3-3 | 0AA0) |
| 60721-3-5 | Class 5B3 on request |
| to EN 60721-3-5 | 0AA0) |
| agriculture acc. to ISO 15003 | (6AG1193-6AA00-0AA0) |
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
| Width | 20 mm |
| Height | 72 mm |
| Depth | 55 mm |
| Weight, approx. | 70 g |
| EMV | Functional Saftey |
| Railway | Environment |
| last modified: | 10/23/2025 |