Especificaciones técnicas
Protección y seguridad
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
|---|
Datos eléctricos
| Supported power supply systems | TT, TN, IT |
|---|---|
| Voltage measurement | Yes |
| without voltage transformer | Yes |
| Current measurement | Yes; max. 3 + neutral conductor |
| Power measurement | Yes |
| Active power measurement | Yes |
| Reactive power measurement | Yes |
| Power factor measurement | Yes |
| Reactive power compensation | Yes |
| Current consumption (rated value) | 12.5 mA |
| Current consumption, max. | 17 mA |
| Power loss, typ. | 1 W; 3x 5 A input current, 3x 230 V AC |
| Supply voltage | Yes |
| Overload current | Yes |
| Monitoring of the supply voltage (PWR-LED) | Yes |
| Measuring procedure for voltage measurement | TRMS |
| Measuring procedure for current measurement | TRMS |
| Curve shape of voltage | Sinusoidal or distorted |
| Measurable line voltage between phase and neutral | 277 V |
| Measurable line voltage between the line | 480 V |
| Power consumption per phase | 60 mW; 300 V AC |
| Impulse voltage resistance 1,2/50µs | 2.5 kV |
| Measurement category for voltage measurement in | CAT II |
| measurable relative current (AC), min. | 1 %; Relative to measuring range; 1 A, 5 A |
| measurable relative current (AC), max. | 100 %; Relative to the secondary rated current 5 A |
| Continuous current with AC, maximum permissible | 5A |
| Apparent power consumption per phase for | 0.6 VA |
| Rated value short-time withstand current restricted | 100 A |
| Measured variable voltage | 0,2 |
| Measured variable current | 0,2 |
| Measured variable apparent power | 0.5 |
| Measured variable active power | 0.5 |
| Measured variable reactive power | 1 |
| Measured variable power factor | 0.5 |
| Measured variable neutral current | 0,2 |
| Between the channels and load voltage L+ | Yes; Including FE |
| Burden power current transformer x/1A, min. | As a function of cable length and cross section, see device manual |
| Burden power current transformer x/5A, min. | As a function of cable length and cross section, see device manual |
Montaje y material
| Color code for module-specific color-coded label | CC20 |
|---|
Condiciones ambientales
| Installation altitude above sea level, max. | 3 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
|---|
Otras características
| Product type designation | AI Energy Meter CT ST |
|---|---|
| FW update possible | Yes |
| based on | 6ES7134-6PA01-0BU0 |
| usable BaseUnits | BU type U0 |
| Energy measurement | Yes |
| Frequency measurement | Yes |
| Active factor measurement | Yes |
| I&M data | Yes; I&M0 to I&M3 |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Cyclic measured value access | Yes |
| Acyclic measured value access | Yes |
| Fixed measured value sets | Yes |
| Freely definable measured value sets | Yes; For cyclic and acyclic measured value access |
| Reparameterization possible in RUN | Yes |
| Calibration possible in RUN | Yes |
| Mounting position | any |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Inputs | 256 byte |
| Outputs | 20 byte |
| Automatic encoding | Yes |
| Mechanical coding element | Yes |
| Type of mechanical coding element | type C |
| 2-wire connection | BU type U0 |
| present | Yes |
| shielded, max. | 200 m |
| unshielded, max. | 200 m |
| Sampling frequency, max. | 2 048 kHz |
| Diagnostic alarm | Yes |
| Limit value alarm | Yes |
| Hardware interrupt lost | Yes |
| Parameter assignment error | Yes |
| Module fault | Yes |
| Channel not available | Yes |
| Overflow/Underflow | Yes |
| Channel status display | Yes; green LED |
| for channel diagnostics | Yes; red Fn LED |
| for module diagnostics | Yes; green/red DIAG LED |
| Type of measured value acquisition | seamless |
| Buffering of measured variables | Yes |
| Parameter length | 128 byte |
| Bandwidth of measured value acquisition | 3.2 kHz; Harmonics: 63 / 50 Hz, 52 / 60 Hz |
| Frequency measurement, min. | 40 Hz |
| Frequency measurement, max. | 70 Hz |
| Internal resistance line conductor and neutral | 1.5 MΩ |
| Input resistance measuring range 0 to 5 A | 25 mΩ; At the terminal |
| Surge strength | 10 A; for 1 minute |
| Zero point suppression | 0 ... 20%, referred to the nominal current |
| Measured variable active energy | 0.5 |
| Measured variable reactive energy | 1 |
| Measured variable phase angle | ±0.5 °; not covered by IEC 61557-12 |
| Measured variable frequency | 0.05; only valid for the permissible voltage measuring range |
| between the channels and backplane bus | Yes |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| horizontal installation, max. | 70 °C; = Tmax |
| vertical installation, min. | -40 °C; = Tmin |
| vertical installation, max. | 50 °C; = Tmax |
| 2-38, max. | horizontal installation |
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
| 60721-3-3 | Class 3B3 on request |
| to EN 60721-3-3 | 0AA0//6AG1193-6AB00-0AA0) |
| 60721-3-6 | degree 3); * |
| to EN 60721-3-6 | 0AA0/6AG1193-6AB00-0AA0) |
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 45 g |
| Secondary side, max. | 300 V |