Relé estático 3RF2, 20A, 110-230V AC
Siemens

Relé estático 3RF2, 20A, 110-230V AC

Relé estático, monofásico 3RF2 ancho de montaje 22,5 mm, 20 A 48-460 V / 110-230 V AC conexión de cable tipo ojal para montaje en superficies refrigerantes existentes

Conexión y cableado
product component removable terminal for auxiliary andYes
for main contacts for JIS cable lugJIS C 2805 R 2-5, 5,5-5, 8-5, 14-5
for DIN cable lug for main contactsDIN 46234-5-2,5, -5-6, -5-10, -5-16, -5-25
for AWG cables for auxiliary and control contacts1x (20 ... 12)
for main contacts with screw-type terminals2 ... 2.5 N·m
Condiciones ambientales
installation altitude at height above sea level maximum1 000 m
Otras características
product brand nameSIRIUS
design of the product1-pole
product type designation3RF21
_1 of the accessories that can be ordered3RF2900-3PA88
_4 of the accessories that can be ordered3RF2920-0GA36
product functionzero-point switching
power loss [V·A] maximum28.6 VA
at AC in hot operating state28.6 W
at AC in hot operating state per pole28.6 W
without load current share typical3.5 W
insulation voltage rated value600 V
surge voltage resistance of main circuit rated value6 kV
protection class IPIP00
protection class IP on the front according to IEC 60529IP00
shock resistance according to IEC 60068-2-2715 g / 11 ms
vibration resistance according to IEC 60068-2-62g
Net Weight0.075 kg
number of poles for main current circuit1
number of NO contacts for main contacts1
number of NC contacts for main contacts0
type of voltage of the operating voltageAC
at 50 Hz rated value48 ... 460 V
at 60 Hz rated value48 ... 460 V
operating frequency rated value50 ... 60 Hz
at 50 Hz40 ... 506 V
at 60 Hz40 ... 506 V
operational current rated value maximum20 A
at AC-1 at 400 V rated value20 A
at AC-51 rated value20 A
according to UL 508 rated value20 A
ampacity maximum20 A
operational current minimum100 mA
rate of voltage rise at the thyristor for main contacts500 V/µs
blocking voltage at the thyristor for main contacts1 200 V
reverse current of the thyristor10 mA
derating temperature40 °C
surge current resistance rated value200 A
I2t value maximum200 A²·s
type of voltage of the control supply voltageAC
at 50 Hz full-scale value for signal<0> recognition40 V
at 60 Hz full-scale value for signal<0> recognition40 V
initial value for signal <1> detection90 V
1 rated value50 Hz
2 rated value60 Hz
symmetrical line frequency tolerance5 Hz
at AC2 mA
control current at AC rated value15 mA
ON-delay time40 ms; additionally max. one half-wave
OFF-delay time40 ms; additionally max. one half-wave
fastening method side-by-side mountingYes
fastening methodscrew fixing
design of the thread of the screw for securing theM4
tightening torque of fixing screw maximum1.5 N·m
tightening torque [lbf·in] of fixing screw maximum13 lbf·in
height85 mm
width22.5 mm
depth48 mm
for main current circuitRing cable lug connection
for auxiliary and control circuitring terminal lug connection
solid1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1 mm²)
finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1 mm²)
finely stranded without core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1 mm²)
for auxiliary and control contacts with screw-type0.5 ... 0.6 N·m
for main contactsM5
of the auxiliary and control contactsM3
for auxiliary and control contacts7 mm
operational current according to UL 508 rated value20 A
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
during operation-25 ... +60 °C
during storage-55 ... +80 °C
due to burst according to IEC 61000-4-42 kV / 5 kHz, behavior criterion 2
due to conductor-earth surge according to IEC 61000-4-52 kV, behavior criterion 2
due to conductor-conductor surge according to IEC1 kV, behavior criterion 2
due to high-frequency radiation according to IEC 61000140 dBuV in the frequency range 0.15 ... 80 MHz, behavior criterion 1
field-based interference according to IEC 61000-4-380 MHz ... 1 GHz 10 V/m, behavior criterion 1
electrostatic discharge according to IEC 61000-4-24 kV contact discharging / 8 kV air discharging, behavior criterion 2
conducted HF interference emissions according toClass A for industrial environment
usablerelays
cylindrical design 10 x 38 mm usablerelays
of back-up R fuse link for semiconductor protection at3NC1425
at NH design usable noteThese fuses have a smaller rated current than the semiconductor relays
at cylindrical design 14 x 51 mm usable noteThese fuses have a smaller rated current than the semiconductor relays
De vice curren t / Ge rä te s trom I e (A)Ambien t te mpe ra ture / Umgebung s te mpe ra tur T a (°C)
last modified:4/4/2026

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito. Si prefieres esperar a que vuelva a haber stock inmediato, déjanos tu email abajo.

Plazo de entrega (días):

Este artículo va bajo pedido.

Avísame cuando esté disponible

Solo usaremos tu email para avisarte de este artículo.

Relé estático 3RF2, 20A, 110-230V AC
€44,11 EUR
€119,22 EUR
3RF2120-3AA24
Plazo de entrega (días):
€44,11 EUR /each
Total:

Accesorios