Contactor, 9A, 4kW, 24V DC, tam. S00, resorte
Siemens

Contactor, 9A, 4kW, 24V DC, tam. S00, resorte

Contactor de potencia, AC-3e/AC-3, 9 A, 4 kW/400 V, 3 polos, 24 V DC, 0,7-1,25* Uc, con integración de diodo supresor, contactos auxiliares: 1 NC, borne de resorte, tamaño: S00, apto para salidas de Plc, no con bloque de contactos auxiliares ampliable

Protección y seguridad
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
safety device type according to IEC 61508-2Type A
Conexión y cableado
size of contactorS00
of contactor typical30 000 000
at contactor for auxiliary contactsSpring-type terminals
for AWG cables for main contacts2x (20 ... 12)
for AWG cables for auxiliary contacts2x (20 ... 12)
AWG number as coded connectable conductor cross20 ... 12
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
at AC-1 at 400 V at ambient temperature 40 °C rated22 A
up to 690 V at ambient temperature 40 °C rated22 A
up to 690 V at ambient temperature 60 °C rated20 A
Prestaciones y durabilidad
B10 value with high demand rate according to SN 319201 000 000
Otras características
product brand nameSIRIUS
product type designation3RT2
at AC in hot operating state0.9 W
at AC in hot operating state per pole0.3 W
without load current share typical2.8 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
at DC6,7 g / 5 ms, 4,2 g / 10 ms
Net Weight0.316 g
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-3095 %
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at 400 V rated value9A
at 500 V rated value7.7 A
at 690 V rated value6.7 A
at AC-4 at 400 V rated value8.5 A
at AC-5a up to 690 V rated value19.4 A
at AC-5b up to 400 V rated value7.4 A
up to 230 V for current peak value n=20 rated value5.3 A
up to 400 V for current peak value n=20 rated value5.3 A
up to 500 V for current peak value n=20 rated value5.3 A
up to 690 V for current peak value n=20 rated value5A
up to 230 V for current peak value n=30 rated value3.5 A
up to 400 V for current peak value n=30 rated value3.5 A
up to 500 V for current peak value n=30 rated value3.6 A
up to 690 V for current peak value n=30 rated value3.3 A
at 24 V rated value20 A
at 60 V rated value20 A
at 110 V rated value2.1 A
at 220 V rated value0.8 A
at 440 V rated value0.6 A
at 600 V rated value0.6 A
at 230 V rated value2.2 kW
limited to 1 s switching at zero current maximum155 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum111 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum66 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum55 A; Use minimum cross-section acc. to AC-1 rated value
at AC-1 maximum1 000 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
maximum750 1/h
at AC-4 maximum250 1/h
type of voltage of the control supply voltageDC
control supply voltage at DC rated value24 V
initial value0.7
full-scale value1.25
design of the surge suppressorsuppressor diode
closing power of magnet coil at DC2.8 W
holding power of magnet coil at DC2.8 W
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
operational current at AC-12 maximum10 A
at 48 V rated value6A
at 125 V rated value2A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
at 480 V rated value7.6 A
at 110/120 V rated value0.33 hp
at 200/208 V rated value2 hp
at 220/230 V rated value3 hp
at 460/480 V rated value5 hp
at 575/600 V rated value7.5 hp
contact rating of auxiliary contacts according to ULA600 / Q600
fastening method side-by-side mountingYes
height70 mm
width45 mm
depth73 mm
forwards10 mm
upwards10 mm
downwards10 mm
at the side0 mm
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
of magnet coilSpring-type terminals
solid2x (0.5 ... 4 mm²)
solid or stranded2x (0,5 ... 4 mm²)
finely stranded with core end processing2x (0.5 ... 2.5 mm²)
finely stranded without core end processing2x (0.5 ... 2.5 mm²)
stranded0.5 ... 4 mm²
mirror contact according to IEC 60947-4-1Yes
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
failure rate [FIT] with low demand rate according to SN100 FIT
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
A1 (+)1/L1
3/L25/L3
A2 (-)2/T1
4/T26/T3
last modified:4/4/2026

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito. Si prefieres esperar a que vuelva a haber stock inmediato, déjanos tu email abajo.

Plazo de entrega (días):

Este artículo va bajo pedido.

Avísame cuando esté disponible

Solo usaremos tu email para avisarte de este artículo.

Contactor, 9A, 4kW, 24V DC, tam. S00, resorte
€37,48 EUR
€101,30 EUR
3RT2016-2KB42
Plazo de entrega (días):
€37,48 EUR /each
Total:

Accesorios