Protección y seguridad
| fuse protection type | none |
|---|---|
| design of the overvoltage protection | max. 32 V |
| property of the output short-circuit proof | Yes |
| galvanic isolation between input and output | Yes |
| galvanic isolation | Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) |
| operating resource protection class | Class I |
| protection class IP | IP20 |
Datos eléctricos
| type of the power supply network | 3-phase AC or DC |
|---|---|
| supply voltage at AC | Derating 323 ... 360 and 550 ... 576 V |
| supply voltage at DC | 500 ... 550 V |
| input voltage at DC | 450 ... 600 V |
| buffering time for rated value of the output current in the event of | 30 ms |
| line frequency | 50/60 Hz |
| current limitation of inrush current at 25 °C maximum | 3A |
| voltage curve at output | Controlled, isolated DC voltage |
| output voltage at DC rated value | 24 V |
| output voltage adjustable | Yes; via display and IO-Link interface |
| adjustable output voltage | 22 ... 28 V; Derating > 24 V: max. 480 W power output (576 W to 45°C) |
| relative overall tolerance of the voltage | 3% |
| behavior of the output voltage when switching on | No overshoot of Vout (soft start) |
| supplied active power typical | 480 W |
| efficiency in percent | 96 % |
| relative control precision of the output voltage with rapid | 1% |
| relative control precision of the output voltage at load step of | 3% |
| response value current limitation | 15 ... 24.5 A |
| design of the current limitation | adjustable via display and IO-Link |
Entradas/Salidas y comunicación
| design of the interface | IO-Link |
|---|---|
| IO-Link protocol | Yes |
| IO-Link transfer rate | COM3 (230.4 kBaud) |
| number of IO-Link ports | 1 |
| point-to-point cycle time between master and IO-Link device | 10 ms |
| protocol between master and IO-Link device Version 1.1 | Yes |
| design of the interface for communication | L+, C/Q, L- (IO-Link): 1 push-in terminal each for 0.2 ... 1.5 mm² |
Prestaciones y durabilidad
| response delay maximum | 0.5 s |
|---|---|
| MTBF at 40 °C | 440 000 h |
Certificados y homologaciones
| CE marking | Yes |
|---|---|
| UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259 |
| UKCA marking | Yes |
| EAC approval | Yes |
| Regulatory Compliance Mark (RCM) | Yes |
| SEMI F47 | Yes |
| CB-certificate | Yes |
Otras características
| minimum rated value | 400 V |
|---|---|
| maximum rated value | 500 V |
| initial value | 323 V |
| full-scale value | 576 V |
| wide range input | Yes |
| operating condition of the mains buffering | at Vin = 400 V |
| I2t value maximum | 0.1 A²·s |
| number of outputs | 1 |
| display version for normal operation | display and 3-color LED for operating, fault and communication status |
| per output | 20 A |
| rated range | 0 ... 20 A; 24 A up to 45 °C; +60 ... +70 °C: derating 3.75%/K |
| display version for overload and short circuit | display and 3-color LED for operating status |
| design of the reset device/resetting mechanism | via display and IO-Link |
| product function communication function | Yes |
| for emitted interference | EN 55022 Class B |
| for mains harmonics limitation | EN 61000-3-2 |
| for interference immunity | EN 61000-6-2 |
| type of electrical connection | screw-type terminals and push-in terminals |
| for auxiliary contacts | PAR SYNC OUT/IN: 1 push-in terminal each for 0.2 ... 1.5 mm² |
| for signaling contact | 13, 14: 1 push-in terminal each for 0.2 ... 1.5 mm² |
| width × height × depth of the enclosure | 59 × 145 × 125 mm |
| installation width × mounting height | 59 mm × 225 mm |
| top | 40 mm |
| bottom | 40 mm |
| left | 0 mm |
| right | 0 mm |
| fastening method | Snaps onto DIN rail EN 60715 35x7.5/15 |
| DIN-rail mounting | Yes |
| housing can be lined up | Yes |
| net weight | 1.15 kg |
| identification link | Yes; acc. to IEC 61406-1:2022 |
| last modified: | 5/5/2026 |