SIPLUS ET 200SP F-PM-E 24VDC/8A PPM RAIL
Siemens

SIPLUS ET 200SP F-PM-E 24VDC/8A PPM RAIL

SIPLUS ET 200SP F-PM-E 24 V DC/8 A PPM RAIL basado en 6ES7136-6PA00-0BC0 con revestimiento conformado, –30…+60 °C, OT1 con ST1/2 (+70 °C durante 10 min), módulo de potencia de seguridad PROFIsafe, 24 V DC, desconexión segura de DQ y F-DQ hasta PL D/SIL2 o PL E/SIL3 2 entradas digitales seguras 1 salida digital segura PPM

Protección y seguridad
Performance level according to ISO 13849-1PLe
SIL acc. to IEC 61508SIL 3
Montaje y material
Color code for module-specific color-coded labelCC52
Condiciones ambientales
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Certificados y homologaciones
China RoHSTUEV
Otras características
Product type designationF-PM-E PPM 24VDC
based on6ES7136-6PA00-0BC0
usable BaseUnitsBU type C0
I&M dataYes; I&M0 to I&M3
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Current consumption (rated value)75 mA; without load
Current consumption, max.21 mA; From the backplane bus
Number of outputs2
Short-circuit protectionYes; Electronic (response threshold 0.7 A to 2.1 A)
up to 60 °C, max.0.3 A
24 VYes; min. L+ (-1.5 V)
Output current, max.600 mA; Total current of all encoders
Power consumption from the backplane bus70 mW
Power loss, typ.5W
Inputs7 byte
Outputs5 byte
Automatic encodingYes
Electronic coding element type FYes
Number of digital inputs2
Sourcing/sinking inputYes; P-reading
Type of input voltageDC
for signal "0"-30 to +5 V
for signal "1"+15 to +30 V
for signal "1", typ.3.7 mA
parameterizableYes
at "0" to "1", min.0.4 ms
at "0" to "1", max.20 ms
at "1" to "0", min.0.4 ms
at "1" to "0", max.20 ms
shielded, max.1 000 m
unshielded, max.500 m
Number of digital outputs1
Digital outputs, parameterizableYes
Response threshold, typ.> 14.8 A
Open-circuit detectionYes
Overload protectionYes
Limitation of inductive shutdown voltage tomax. 1.5 V
with resistive load, max.8A
on lamp load, max.100 W
lower limit3Ω
upper limit2 000 Ω
for signal "1", min.24 V; L+ (-0.5 V)
for signal "1" rated value8A
for signal "0" residual current, max.1.5 mA; PP-switching: max. 1.5 mA; PM-switching: max. 1 mA
with inductive load, max.0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical
Current per channel, max.8 A; note derating data in the manual
Current per module, max.8 A; note derating data in the manual
up to 40 °C, max.8 A; note derating data in the manual
up to 50 °C, max.6 A; note derating data in the manual
Diagnostics functionYes; See Chapter "Alarms/diagnostic messages" in the manual
Diagnostic alarmYes
RUN LEDYes; green LED
ERROR LEDYes; red LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; green/red DIAG LED
between the channels and backplane busYes
Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Suitable for safety functionsYes
50716specific application under consideration of all local regulations.
Low demand mode: PFDavg in accordance with< 2.00E-04
High demand/continuous mode: PFH in accordance< 1.00E-08 1/h
EN 50121-3-2Yes; EMC for rail vehicles
EN 50121-4Yes; EMC for signal and telecommunications systems
EN 50125-1Yes; Rail vehicles - see ambient conditions
EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions;
EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
horizontal installation, min.-30 °C; = Tmin (incl. condensation/frost)
vertical installation, min.-30 °C; = Tmin
vertical installation, max.50 °C; = Tmax
2-38, max.horizontal installation
Resistant to commercially available coolants andYes; Incl. diesel and oil droplets in the air
60721-3-3Class 3B3 on request
to EN 60721-3-30AA0)
60721-3-5Class 5B3 on request
to EN 60721-3-50AA0)
agriculture acc. to ISO 15003(6AG1193-6AA00-0AA0)
conditions acc. to EN 60721, EN 60654-4 andduring operation!
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Electronic equipment on rolling stock acc. to EN 50155Yes; Class PC2 protective coating acc. to EN 50155:2017
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical InsulatingYes; Conformal coating, Class A
Width20 mm
Height72 mm
Depth55 mm
Weight, approx.70 g
IDEA4
UNSPSC15
EMVFunctional Saftey
RailwayEnvironment
TUEVConfirmation
last modified:10/23/2025

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito. Si prefieres esperar a que vuelva a haber stock inmediato, déjanos tu email abajo.