| Product type designation | F-TM Count 1x1Vpp sin/cos HF |
|---|
| FW update possible | Yes |
|---|
| based on | 6ES7136-6CB00-0CA0 |
|---|
| usable BaseUnits | BU type A0 |
|---|
| I&M data | Yes; I&M0 to I&M3 |
|---|
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
|---|
| Rated value (DC) | 24 V |
|---|
| permissible range, lower limit (DC) | 20.4 V |
|---|
| permissible range, upper limit (DC) | 28.8 V |
|---|
| Reverse polarity protection | Yes |
|---|
| Current consumption, max. | 50 mA; without load, 150 mA with 300 mA encoder load |
|---|
| Output current, max. | 300 mA |
|---|
| Power loss, typ. | 1.25 W |
|---|
| Inputs | 14 byte; S7-300/400F CPU, 13 byte |
|---|
| Outputs | 5 byte; S7-300/400F CPU, 4 byte |
|---|
| Automatic encoding | Yes |
|---|
| Electronic coding element type H | Yes |
|---|
| Number of digital inputs | 1; (counter input) |
|---|
| Digital inputs, parameterizable | Yes |
|---|
| Gate start/stop | Yes |
|---|
| Counter for incremental encoder | Yes |
|---|
| Number, max. | 1 |
|---|
| Type of input voltage | sin/cos 1 Vpp |
|---|
| Minimum pulse width for program reactions | 2.5 µs |
|---|
| parameterizable | Yes |
|---|
| shielded, max. | 150 m |
|---|
| Incremental encoder (symmetrical) | Yes; up to 200 kHz depending on cable type and length |
|---|
| Input voltage | 1 Vpp, centered at 2.5 V offset |
|---|
| Input frequency, max. | 200 kHz |
|---|
| Counting frequency, max. | 800 kHz; with quadruple evaluation |
|---|
| Incremental encoder with A/B tracks, 90° phase offset | Yes; sin/cos |
|---|
| Diagnostics function | Yes; see chapter "Diagnostic Messages" in the manual |
|---|
| Diagnostic alarm | Yes |
|---|
| Monitoring the supply voltage | Yes |
|---|
| Wire break | Yes |
|---|
| short-circuit | Yes |
|---|
| A/B transition error at incremental encoder | Yes |
|---|
| RUN LED | Yes; green LED |
|---|
| ERROR LED | Yes; red LED |
|---|
| Monitoring of the supply voltage (PWR-LED) | Yes; green LED |
|---|
| Channel status display | Yes; green LED |
|---|
| for channel diagnostics | Yes; red LED |
|---|
| for module diagnostics | Yes; green/red DIAG LED |
|---|
| Counter | Yes |
|---|
| Number of counters | 1 |
|---|
| Safe Operating Stop (SOS) | Yes |
|---|
| Safely-Limited Speed (SLS) | Yes |
|---|
| Safe Direction (SDI) | Yes |
|---|
| Safe Speed Monitor (SSM) | Yes |
|---|
| Continuous counting | Yes |
|---|
| Counter response parameterizable | Yes |
|---|
| Software gate | Yes |
|---|
| Counting range, parameterizable | Yes |
|---|
| Frequency measurement, min. | 0.04 Hz |
|---|
| Frequency measurement, max. | 800 kHz; with quadruple evaluation |
|---|
| Cycle duration measurement, min. | 1 µs |
|---|
| Cycle duration measurement, max. | 25 s |
|---|
| Velocity measurement, min. | 0 (speed in configured units per selected time basis - speed*1 000) |
|---|
| between the channels | No; Only one channel is available |
|---|
| between the channels and backplane bus | Yes |
|---|
| Isolation tested with | 750 V DC (type test) and according to EN 50155 (routine test) |
|---|
| Suitable for safety functions | Yes |
|---|
| 50716 | specific application under consideration of all local regulations. |
|---|
| low demand mode: PFDavg in accordance with SIL1 | < 2.00E-03 signal monitoring disabled |
|---|
| Low demand mode: PFDavg in accordance with | < 3.00E-05 |
|---|
| high demand/continuous mode: PFH in accordance | < 3.00E-08 1/h signal monitoring disabled |
|---|
| High demand/continuous mode: PFH in accordance | < 1.00E-09 1/h |
|---|
| EN 50121-3-2 | Yes; EMC for rail vehicles |
|---|
| EN 50121-4 | Yes; EMC for signal and telecommunications systems |
|---|
| EN 50121-5 | Yes; EMC for fixed installations and railway power supply equipment |
|---|
| EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
|---|
| EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
|---|
| EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; |
|---|
| EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
|---|
| Fire protection acc. to EN 45545-2 | Yes; For proof of conformity, see Service & Support |
|---|
| horizontal installation, min. | -25 °C; = Tmin (incl. condensation/frost) |
|---|
| vertical installation, min. | -25 °C; = Tmin |
|---|
| vertical installation, max. | 55 °C; = Tmax |
|---|
| 2-38, max. | horizontal installation |
|---|
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
|---|
| 60721-3-3 | Class 3B3 on request |
|---|
| to EN 60721-3-3 | 0AA0//6AG1193-6AB00-0AA0) |
|---|
| 60721-3-5 | Class 5B3 on request |
|---|
| to EN 60721-3-5 | 0AA0/6AG1193-6AB00-0AA0) |
|---|
| agriculture acc. to ISO 15003 | (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0) |
|---|
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
|---|
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
|---|
| Electronic equipment on rolling stock acc. to EN 50155 | Yes; class PC2 protective coating acc. to EN 50155 |
|---|
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
|---|
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
|---|
| Width | 15 mm |
|---|
| Height | 73 mm |
|---|
| Depth | 58 mm |
|---|
| Weight, approx. | 42 g |
|---|
| Functional Saftey | Railway |
|---|
| TUEV | TUEV |
|---|
| last modified: | 7/3/2026 |
|---|