Especificaciones técnicas
Generalidades
| Series mode interference (peak value of interference < | 60 dB |
|---|
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Short-circuit protection | Yes |
| Isolation tested with | 707 V DC (type test) |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
Datos eléctricos
| Current consumption, max. | 25 mA; without sensor supply |
|---|---|
| Output current, max. | 20 mA; max. 50 mA per channel for a duration < 10 s |
| Power loss, typ. | 0.65 W; without sensor supply |
| For current measurement | 4 |
| permissible input current for current input (destruction limit), | 50 mA |
| Interference voltage suppression for interference | 10 / 50 / 60 Hz |
| for current measurement as 2-wire transducer | Yes |
| Current, relative to input range, (+/-) | 1% |
| Monitoring the supply voltage | Yes |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Montaje y material
| Color code for module-specific color-coded label | CC03 |
|---|
Condiciones ambientales
| Installation altitude above sea level, max. | 5 000 m |
|---|
Certificados y homologaciones
| China RoHS | CCC-Ex |
|---|
Otras características
| Product type designation | AI 4xI 2-wire HART |
|---|---|
| FW update possible | Yes |
| based on | 6ES7134-6TD00-0CA1 |
| usable BaseUnits | BU type A0, A1 |
| I&M data | Yes; I&M0 to I&M3 |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Reparameterization possible in RUN | Yes |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| 24 V | Yes |
| Address space per module, max. | 8 byte; + 1 byte for QI information |
| Address space per module with HART, max. | 28 byte; + 1 byte for QI information |
| Automatic encoding | Yes |
| Mechanical coding element | Yes |
| Type of mechanical coding element | Type A |
| Number of analog inputs | 4; Differential inputs |
| 4 mA to 20 mA | Yes; 15 bit + sign |
| Input resistance (4 mA to 20 mA) | 280 Ω; + approx. 0.35 V diode forward voltage |
| shielded, max. | 800 m |
| Measurement principle | integrating (Sigma-Delta) |
| Resolution with overrange (bit including sign), max. | 16 bit |
| Integration time, parameterizable | Yes; channel by channel |
| Number of smoothing levels | 4; None; 4/8/16 times |
| Parameterizable | Yes |
| Linearity error (relative to input range), (+/-) | 0.01 % |
| Temperature error (relative to input range), (+/-) | 0.005 %/K |
| Crosstalk between the inputs, min. | 60 dB |
| Diagnostics function | Yes |
| Diagnostic alarm | Yes |
| Limit value alarm | Yes |
| Wire break | Yes; channel by channel |
| Group error | Yes |
| Overflow/Underflow | Yes; channel by channel |
| Channel status display | Yes; green LED |
| for channel diagnostics | Yes; red LED |
| for module diagnostics | Yes; green/red DIAG LED |
| between the channels and backplane bus | Yes |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost); start-up @ -30 °C |
| horizontal installation, max. | 60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or |
| vertical installation, min. | -40 °C; = Tmin (incl. condensation/frost); start-up @ -30 °C |
| vertical installation, max. | 50 °C; = Tmax |
| 2-38, max. | conditions) |
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
| 60721-3-3 | Class 3B3 on request |
| to EN 60721-3-3 | 0AA0) |
| 60721-3-6 | request |
| to EN 60721-3-6 | 0AA0) |
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 31 g |
| EMV | For use in hazardous locations |
| last modified: | 10/23/2025 |