Especificaciones técnicas
Generalidades
| Series mode interference (peak value of interference < | 70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB |
|---|
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Isolation tested with | 707 V DC (type test) |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
Datos eléctricos
| Current consumption (rated value) | 25 mA; rated voltage, all channels active, no load |
|---|---|
| Current consumption, max. | 25 mA; worst case voltage, all channels active, max. load, no derating |
| Power loss, typ. | 0.7 W; rated voltage, 50 % active channels, 50 % of range |
| permissible input voltage for voltage input (destruction limit), | 30 V |
| Interference voltage suppression for interference | 16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60) |
| for voltage measurement | Yes |
| Voltage, relative to input range, (+/-) | 0.9 % |
| Monitoring the supply voltage | Yes |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Montaje y material
| Color code for module-specific color-coded label | CC02 |
|---|
Condiciones ambientales
| Installation altitude above sea level, max. | 5 000 m |
|---|
Certificados y homologaciones
| China RoHS | CCC-Ex |
|---|
Otras características
| Product type designation | AI 8xU BA |
|---|---|
| FW update possible | Yes |
| based on | 6ES7134-6FF00-0AA1 |
| usable BaseUnits | BU type A0, A1 |
| I&M data | Yes; I&M0 to I&M3 |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Address space per module, max. | 16 byte |
| Automatic encoding | Yes |
| Mechanical coding element | Yes |
| Type of mechanical coding element | type B |
| 1-wire connection | BU type A0, A1 |
| 2-wire connection | BU type A0, A1 |
| Number of analog inputs | 8; Single-ended |
| Cycle time (all channels), min. | 1 ms; per channel |
| 0 to +10 V | Yes; 15 bit |
| Input resistance (0 to 10 V) | 100 kΩ |
| 10 V to +10 V | Yes; 16 bit incl. sign |
| Input resistance (-10 V to +10 V) | 100 kΩ |
| shielded, max. | 200 m |
| Resolution with overrange (bit including sign), max. | 16 bit |
| Integration time, parameterizable | Yes |
| Conversion time (per channel) | 180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms |
| Number of smoothing levels | 4 |
| Parameterizable | Yes |
| Step: None | Yes |
| Step: low | Yes; 4x smoothing |
| Step: Medium | Yes; 8x smoothing |
| Step: High | Yes; 16x smoothing |
| Linearity error (relative to input range), (+/-) | 0.01 % |
| Temperature error (relative to input range), (+/-) | 0.005 %/K |
| Crosstalk between the inputs, min. | -50 dB |
| Diagnostics function | Yes |
| Diagnostic alarm | Yes |
| Group error | Yes |
| Overflow/Underflow | Yes; module-wise |
| Channel status display | Yes; green LED |
| for module diagnostics | Yes; green/red DIAG LED |
| between the channels and backplane bus | Yes |
| signed firmware update | Yes; firmware V2.0.0 or higher |
| safely removing data | Yes; firmware V2.0.0 or higher |
| data integrity | Yes; firmware V2.0.0 or higher |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| horizontal installation, max. | 60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or |
| vertical installation, min. | -40 °C; = Tmin |
| vertical installation, max. | 50 °C; = Tmax |
| 2-38, max. | horizontal installation |
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
| 60721-3-3 | Class 3B3 on request |
| to EN 60721-3-3 | 0AA0) |
| 60721-3-6 | request |
| to EN 60721-3-6 | 0AA0) |
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 31 g |
| EMV | For use in hazardous locations |
| last modified: | 3/10/2026 |