Especificaciones técnicas
Protección y seguridad
| test voltage for isolation test | 2.5 kV |
|---|---|
| design of the fuse link for short-circuit protection of the auxiliary | fuse gL/gG: 4 A |
| protection class IP on the front according to IEC 60529 | IP20 |
Datos eléctricos
| power loss [W] maximum | 2W |
|---|---|
| insulation voltage for overvoltage category III according to IEC | 300 V |
| surge voltage resistance rated value | 4 000 V |
| thermal current | 5A |
| power supply influence | 1% in the whole voltage range to the set runtime |
| type of voltage of the control supply voltage | AC/DC |
| control supply voltage frequency 1 | 50 ... 60 Hz |
| control supply voltage at DC rated value | 12 ... 240 V |
| control supply voltage 1 at DC | 12 ... 240 V |
| switching capacity current with inductive load | 0.01 ... 3 A |
Conexión y cableado
| operating frequency with 3RT2 contactor maximum | 5 000 1/h |
|---|---|
| product component removable terminal for auxiliary and | Yes |
| for AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
Montaje y material
| material of switching contacts | AgSnO2 |
|---|
Condiciones ambientales
| vibration resistance according to IEC 60068-2-6 | 10 ... 55 Hz / 0.35 mm |
|---|---|
| installation altitude at height above sea level maximum | 2 000 m |
Otras características
| product brand name | SIRIUS |
|---|---|
| design of the product | OFF-delay without control signal, non-volatile, passing make contact |
| product type designation | 3RP25 |
| relay output | Yes |
| degree of pollution | 3 |
| shock resistance according to IEC 60068-2-27 | 11 g / 15 ms |
| mechanical service life (operating cycles) typical | 10 000 000 |
| adjustable time | 0.05 ... 600 s |
| adjustable time note | minimum value at function N = 0.5 s |
| relative setting accuracy relating to full-scale value | 5 %; +/- |
| recovery time | 250 ms |
| relative repeat accuracy | 1 %; +/- |
| influence of the surrounding temperature | 1% in the whole temperature range to the set runtime |
| Net Weight | 0.158 kg |
| initial value | 0.85 |
| full-scale value | 1.1 |
| passing make contact | Yes |
| OFF delay | Yes |
| delayed switching | 0 |
| instantaneous contact | 0 |
| non-volatile | Yes |
| EMC emitted interference according to IEC 61812-1 | ambience A (industrial sector) |
| EMC immunity according to IEC 61812-1 | corresponds to degree of severity 3 |
| due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
| due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| due to conductor-conductor surge according to IEC | 1 kV |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
| category according to EN 954-1 | none |
| type of insulation | Basic insulation |
| type of electrical connection | screw terminal |
| for auxiliary and control circuit | screw-type terminals |
| solid | 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) |
| finely stranded with core end processing | 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²) |
| tightening torque | 0.6 ... 0.8 N·m |
| design of the thread of the connection screw | M3 |
| mounting position | any |
| fastening method | screw and snap-on mounting onto 35 mm DIN rail |
| height | 100 mm |
| width | 22.5 mm |
| depth | 90 mm |
| forwards | 0 mm |
| backwards | 0 mm |
| upwards | 0 mm |
| downwards | 0 mm |
| relative humidity during operation | 10 ... 95 % |
| ates/Test Report | ate |
| 16 NC | 18 NO |
| last modified: | 5/29/2026 |