Especificaciones técnicas
Datos eléctricos
| power loss [W] maximum | 2W |
|---|---|
| power loss [V·A] maximum | 5 VA |
| surge voltage resistance rated value | 6 kV |
| thermal current of the switching element with contacts | 5A |
| voltage monitoring | Yes |
| current monitoring | Yes |
| overcurrent detection 1 phase | Yes |
| undercurrent detection 1 phase | Yes |
| adjustable open/closed-circuit current principle | Yes |
| type of voltage of the control supply voltage | AC/DC |
| control supply voltage rated value | 24 ... 240 V |
| control supply voltage at DC rated value | 24 ... 240 V |
| supply voltage frequency for auxiliary and control circuit | 50 ... 60 Hz |
| supply voltage frequency rated value | 60 ... 50 Hz |
| type of current for monitoring | AC/DC |
| measurable current | 0.003 ... 10 A |
| measurable voltage at AC | 0.1 ... 760 V |
| adjustable current response value current limited to 5 s | 15 A |
| adjustable switching hysteresis for measured current value | 0 ... 5 000 mA |
| buffering time in the event of power failure minimum | 20 ms |
| number of poles for main current circuit | 1 |
| operating voltage rated value | 24 ... 240 V |
| operational current at 17 V minimum | 5 mA |
| continuous current of the DIAZED fuse link of the output | 6A |
| between the voltage supply and other circuits | Yes |
Medición y rango
| relative metering precision | 10 % |
|---|
Conexión y cableado
| operating frequency with 3RT2 contactor maximum | 5 000 1/h |
|---|---|
| product component removable terminal for auxiliary and | Yes |
| for AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
| tightening torque with screw-type terminals | 0.6 ... 0.8 N·m |
Condiciones ambientales
| installation altitude at height above sea level maximum | 2 000 m |
|---|
Otras características
| product brand name | SIRIUS |
|---|---|
| product type designation | 3UG5 |
| product function | digitally adjustable monitoring relay for electrical variables |
| design of the display | LCD |
| degree of pollution | 3 |
| shock resistance according to IEC 60068-2-27 | sinusoidal half-wave 15 g / 11 ms |
| mechanical service life (operating cycles) typical | 10 000 000 |
| relative repeat accuracy | 1% |
| Net Weight | 0.188 kg |
| auto-RESET | Yes |
| manual RESET | Yes |
| initial value | 0.85 |
| full-scale value | 1.1 |
| when starting | 0 ... 999.8 s |
| accuracy of digital display | +/-1 digit |
| number of NC contacts delayed switching | 0 |
| number of NO contacts delayed switching | 0 |
| number of CO contacts delayed switching | 2 |
| due to burst according to IEC 61000-4-4 | 2 kV |
| due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| due to conductor-conductor surge according to IEC | 1 kV |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| between input and output | Yes |
| between the outputs | Yes |
| type of electrical connection | screw terminal |
| solid | 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) |
| finely stranded with core end processing | 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²) |
| mounting position | any |
| fastening method | screw and snap-on mounting |
| height | 100 mm |
| width | 22.5 mm |
| depth | 90 mm |
| forwards | 0 mm |
| backwards | 0 mm |
| upwards | 0 mm |
| downwards | 0 mm |
| I IN | 11 |