Especificaciones técnicas
Protección y seguridad
| Reverse polarity protection | Yes |
|---|---|
| Isolation tested with | 750 V DC (type test) and according to EN 50155 (routine test) |
| Fire protection acc. to EN 45545-2 | Yes; For proof of conformity, see Service & Support |
| Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
Datos eléctricos
| Current consumption, typ. | 20 mA |
|---|---|
| Current consumption, max. | 25 mA |
| Power loss, typ. | 0.5 W |
| Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Entradas/Salidas y comunicación
| Interface type | CAN according to CiA 303-1 |
|---|---|
| between backplane bus and interface | Yes |
Montaje y material
| Color code for module-specific color-coded label | CC00 |
|---|
Condiciones ambientales
| Installation altitude above sea level, max. | 2 000 m |
|---|---|
| Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
Otras características
| Product type designation | CM 1x CAN ST |
|---|---|
| FW update possible | Yes |
| based on | 6ES7137-6EA00-0BA0 |
| usable BaseUnits | BU type A0 |
| I&M data | Yes; I&M0 to I&M3 |
| Module swapping during operation (hot swapping) | Yes |
| STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Address space per module, max. | 256 byte |
| Isolated | Yes; 500 V AC or 707 V DC |
| Number of ports | 1 |
| Design of the connection | Push-in terminal |
| CAN operating modes | CAN Standard CAN 2.0A/B; CANopen Manager / Slave acc. to CiA |
| Specification acc. to CiA | CiA 301 & CiA 302 |
| Transmission rate, min. | 10 kbit/s |
| Transmission rate, max. | 1 000 kbit/s |
| max. number of devices | 60 |
| Number of SDOs in parallel | 16; Parallel |
| Number of PDOs | 128; Send / receive |
| Node/life-guarding | Yes |
| Heartbeat | Yes |
| SYNC | Yes |
| Alarms | Yes |
| Diagnostics function | Yes |
| RUN LED | Yes |
| ERROR LED | Yes |
| EN 50121-3-2 | Yes; EMC for rail vehicles |
| EN 50121-4 | Yes; EMC for signal and telecommunications systems |
| EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
| EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
| EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; |
| EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
| horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| vertical installation, min. | -40 °C; = Tmin |
| vertical installation, max. | 50 °C; = Tmax |
| ceiling installation, min. | -40 °C; = Tmin |
| ceiling installation, max. | 50 °C; = Tmax |
| floor installation, min. | -40 °C; = Tmin |
| floor installation, max. | 50 °C; = Tmax |
| 2-38, max. | horizontal installation |
| Resistant to commercially available coolants and | Yes; Incl. diesel and oil droplets in the air |
| 60721-3-3 | Class 3B3 on request |
| to EN 60721-3-3 | 0AA0) |
| 60721-3-5 | Class 5B3 on request |
| to EN 60721-3-5 | 0AA0) |
| agriculture acc. to ISO 15003 | (6AG1193-6AA00-0AA0) |
| conditions acc. to EN 60721, EN 60654-4 and | during operation! |
| Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
| Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Qualification and Performance of Electrical Insulating | Yes; Conformal coating, Class A |
| to SIMATIC S7-1200 | Yes |
| to SIMATIC S7-1500 | Yes |
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
| Weight, approx. | 32 g |
| last modified: | 10/23/2025 |