Arrancador suave SIRIUS, 210A, resorte
Siemens

Arrancador suave SIRIUS, 210A, resorte

Arrancadores suaves SIRIUS 200-480 V 210 A, 110-250 V AC bornes de resorte de seguridad

🔌 Comunicación3RW5980-0CS00
Protección y seguridad
performance level (PL) according to ISO 13849-1PL c
category according to ISO 13849-12
according to IEC 61508SIL 1
safety device type according to IEC 61508-2Type B
PFHD with high demand rate according to IEC 615081E-6 1/h
PFDavg with low demand rate according to IEC 615080.09
hardware fault tolerance according to IEC 615080
T1 value of service life according to IEC 6150820 a
Safety Integrity Level (SIL) according to IEC 61508 relatingSIL 1
hardware fault tolerance according to IEC 61508 relating to0
Entradas/Salidas y comunicación
of communication module PROFINET standard usable3RW5980-0CS00
of communication module PROFINET high-feature usable3RW5950-0CH00
of communication module PROFIBUS usable3RW5980-0CP00
of communication module Modbus TCP usable3RW5980-0CT00
of communication module Modbus RTU usable3RW5980-0CR00
of communication module Ethernet/IP3RW5980-0CE00
PROFINET standardYes
PROFINET high-featureYes
EtherNet/IPYes
Modbus RTUYes
Modbus TCPYes
PROFIBUSYes
Conexión y cableado
of the redundant contactor for applications > SIL 13RT1075
of the redundant contactor for applications > SIL 1 at3RT1075
spring-loaded terminalYes
removable terminal for control circuitYes
for DIN cable lug for main contacts stranded2x (50 ... 240 mm²)
for DIN cable lug for main contacts finely stranded2x (70 ... 240 mm²)
for AWG cables for control circuit solid2x (24 ... 16)
for AWG cables for control circuit finely stranded with2x (24 ... 16)
for main contacts with screw-type terminals14 ... 24 N·m
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
Prestaciones y durabilidad
B10d value147 000
Certificados y homologaciones
ATEXYes
according to ATEX directive 2014/34/EUBVS 18 ATEX F 003 X
Otras características
product brand nameSIRIUS
product categoryHybrid switching devices
product type designation3RW55
of high feature HMI module usable3RW5980-0HF00
of circuit breaker usable at 400 V3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V3VA2325-7MN32-0AA0; Type of coordination 1, Iq = 65 kA, CLASS 10
of the gG fuse usable up to 690 V2x3NA3354-6; Type of coordination 1, Iq = 65 kA
of back-up R fuse link for semiconductor protection3NE3333; Type of coordination 2, Iq = 65 kA
starting voltage [%]20 ... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0 ... 360 s
ramp-down time of soft starter0 ... 360 s
start torque [%]10 ... 100 %
stopping torque [%]10 ... 100 %
torque limitation [%]20 ... 200 %
current limiting value [%] adjustable125 ... 800 %
breakaway voltage [%] adjustable40 ... 100 %
breakaway time adjustable0 ... 2 s
number of parameter sets3
accuracy class5 (based on IEC 61557-12)
CE markingYes
UL approvalYes
CSA approvalYes
HMI-High FeatureYes
is supported HMI-High FeatureYes
product feature integrated bypass contact systemYes
number of controlled phases3
current unbalance limiting value [%]10 ... 60 %
ground-fault monitoring limiting value [%]10 ... 95 %
for main current circuit100 ms
for control circuit100 ms
idle time adjustable0 ... 255 s
insulation voltage rated value480 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1 400 V
service factor1.15
surge voltage resistance rated value6 kV
between main and auxiliary circuit480 V; does not apply for thermistor connection
shock resistance15 g / 11 ms, from 6 g / 11 ms with potential contact lifting
vibration resistance15 mm up to 6 Hz; 2 g up to 500 Hz
recovery time after overload trip adjustable60 ... 1 800 s
utilization category according to IEC 60947-4-2AC 53a
Net Weight11.688 kg
ramp-up (soft starting)Yes
soft stoppingYes
breakaway pulseYes
adjustable current limitationYes
creep speed in both directions of rotationYes
pump stopYes
DC brakingYes
motor heatingYes
min/max pointerYes
trace functionYes
intrinsic device protectionYes
evaluation of thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
inside-delta circuitYes
auto-RESETYes
manual RESETYes
remote resetYes
communication functionYes
operating measured value displayYes
event listYes
error logbookYes
via software parameterizableYes
via software configurableYes
firmware updateYes
voltage rampYes
torque controlYes
combined brakingYes
analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
programmable control inputs/outputsYes
condition monitoringYes
automatic parameterisationYes
application wizardsYes
alternative stopping modeYes
emergency operation modeYes
reversing operationYes
soft starting at heavy starting conditionsYes
at 40 °C rated value210 A
at 40 °C rated value minimum42 A
at 50 °C rated value186 A
at 60 °C rated value170 A
rated value200 ... 480 V
at inside-delta circuit rated value200 ... 480 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at-15 %
relative positive tolerance of the operating voltage at10 %
at 230 V at 40 °C rated value55 kW
at 230 V at inside-delta circuit at 40 °C rated value110 kW
at 400 V at 40 °C rated value110 kW
at 400 V at inside-delta circuit at 40 °C rated value200 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
minimum load [%]10 %; Relative to set Ie
at 40 °C after startup63 W
at 50 °C after startup56 W
at 60 °C after startup51 W
at 40 °C during startup3 550 W
at 50 °C during startup2 967 W
at 60 °C during startup2 605 W
type of the motor protectionElectronic, tripping in the event of thermal overload of the motor
type of voltage of the control supply voltageAC
at 50 Hz110 ... 250 V
at 60 Hz110 ... 250 V
control supply voltage frequency50 ... 60 Hz
control supply current in standby mode rated value100 mA
holding current in bypass operation rated value150 mA
inrush current by closing the bypass contacts maximum0.87 A
design of the overvoltage protectionVaristor
number of digital inputs4
with fail-safe1
parameterizable4
number of digital outputs3
Number of digital outputs with fail-safe1
number of digital outputs parameterizable2
number of digital outputs not parameterizable1
number of analog outputs1
at AC-15 at 250 V rated value3A
at DC-13 at 24 V rated value1A
fastening methodscrew fixing
height393 mm
width210 mm
depth203 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
width of connection bar maximum45 mm
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
for control circuit solid2x (0.25 ... 1.5 mm²)
between soft starter and motor maximum800 m
at the digital inputs at DC maximum1 000 m
for auxiliary and control contacts with screw-type0.8 ... 1.2 N·m
during storage and transport-40 ... +80 °C
during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
usable for Standard Faults up to 575/600 VType: Class J / L, max. 700 A; Iq = 10 kA
usable for High Faults up to 575/600 V according toType: Class J / L, max. 700 A; Iq = 100 kA
usable for Standard Faults at inside-delta circuit upType: Class J / L, max. 700 A; Iq = 10 kA
usable for High Faults at inside-delta circuit up toType: Class J / L, max. 700 A; Iq = 100 kA
at 200/208 V at 50 °C rated value60 hp
at 220/230 V at 50 °C rated value60 hp
at 460/480 V at 50 °C rated value150 hp
contact rating of auxiliary contacts according to ULR300-B300
product function suitable for safety functionYes
safety-related switching OFFYes
safe stateOpen load circuit
function test interval maximum1a
stop category according to IEC 60204-10
average diagnostic coverage level (DCavg)90 %
MTTFd39 a
Safety Integrity Level (SIL) according to IEC 62061SIL 1
PFHD with high demand rate according to IEC 620611E-6 1/h
Safe failure fraction (SFF)60 %
protection class IP on the front according to IEC 60529IP00; IP20 with cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with cover
IECExYes
tificateates/Test Report
1/L13/L2
5/L3A1
13 NO23 NO
F-DIL+
DI 2DI 3
AQ I+AQ U+
98 NO96 NC