Especificaciones técnicas
Protección y seguridad
| intrinsic device protection | Yes |
|---|---|
| motor overload protection | Yes |
| adjustable motor current for motor overload protection | 23 A |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
Datos eléctricos
| adjustable current limitation | Yes |
|---|---|
| insulation voltage rated value | 600 V |
| blocking voltage of the thyristor maximum | 1 600 V |
| operating voltage at standard circuit rated value | 400 ... 600 V |
| relative negative tolerance of the operating voltage at | -15 % |
| relative positive tolerance of the operating voltage at | 10 % |
| continuous operating current [% of Ie] at 40 °C | 115 % |
| power loss [W] at operational current at 40 °C during | 19 W |
| type of voltage of the control supply voltage | AC/DC |
| control supply voltage frequency 1 rated value | 50 Hz |
| control supply voltage frequency 2 rated value | 60 Hz |
| relative negative tolerance of the control supply voltage | -10 % |
| relative positive tolerance of the control supply voltage | 10 % |
| control supply voltage 1 at AC at 50 Hz | 110 ... 230 V |
| control supply voltage 1 at AC at 60 Hz | 110 ... 230 V |
| relative negative tolerance of the control supply voltage at | -15 % |
| relative positive tolerance of the control supply voltage at | 10 % |
| control supply voltage 1 at DC | 110 ... 230 V |
| number of poles for main current circuit | 3 |
| for main current circuit | screw-type terminals |
Condiciones ambientales
| installation altitude at height above sea level | 5 000 m |
|---|
Otras características
| product brand name | SIRIUS |
|---|---|
| integrated bypass contact system | Yes |
| thyristors | Yes |
| external reset | Yes |
| degree of pollution | 3, acc. to IEC 60947-4-2 |
| reference code according to EN 61346-2 | Q |
| operating frequency rated value | 50 ... 60 Hz |
| relative negative tolerance of the operating frequency | -10 % |
| relative positive tolerance of the operating frequency | 10 % |
| minimum load [%] | 20 % |
| display version for fault signal | red |
| size of engine control device | S0 |
| width | 45 mm |
| height | 125 mm |
| depth | 155 mm |
| fastening method | screw and snap-on mounting |
| upwards | 60 mm |
| downwards | 40 mm |
| wire length maximum | 300 m |
| for auxiliary and control circuit | screw-type terminals |
| number of NC contacts for auxiliary contacts | 0 |
| number of NO contacts for auxiliary contacts | 2 |
| number of CO contacts for auxiliary contacts | 1 |
| solid | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² |
| finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) |
| using the front clamping point | 1x 8, 2x (16 ... 10) |
| for auxiliary contacts | 2x (20 ... 14) |
| for auxiliary contacts finely stranded with core end | 2x (20 ... 16) |
| derating temperature | 40 °C |
| contact rating of auxiliary contacts according to UL | B300 / R300 |
| ates/Test Report | ate |
| other | Railway |
| 1/L1 | 3/L2 |
| 5/L3 | A1 |
| 14/24 | 95 |
| ON/RUN | BYPASSED |
| 13 NO | 23 NO |
| 96 NC | 98 NO |