Especificaciones técnicas
Protección y seguridad
| intrinsic device protection | Yes |
|---|---|
| for power supply reverse polarity protection | Yes |
| product function short circuit protection | Yes |
| design of short-circuit protection | fuse |
| performance level (PL) according to ISO 13849-1 | PL e |
| category according to ISO 13849-1 | 4 |
| device type according to ISO 13849-1 | 1 |
| Safety Integrity Level (SIL) according to IEC 61508 | SIL 3 |
| safety device type according to IEC 61508-2 | Type B |
| PFH according to IEC 61508 relating to SIL | 6E-9 1/h; for switching frequency 30/h |
| PFDavg with low demand rate according to IEC 61508 | 9E-7; for switching frequency 30/h |
| hardware fault tolerance according to IEC 61508 | 1 |
| touch protection against electrical shock | finger-safe |
| protection class IP on the front according to IEC 60529 | IP20 |
| touch protection on the front according to IEC 60529 | finger-safe |
| Safety Integrity Level (SIL) according to IEC 61508 relating | SIL 1 |
| hardware fault tolerance according to IEC 61508 relating to | 1 |
| type of the motor protection | solid-state |
Seguridad funcional
| Safety Integrity Level (SIL) according to IEC 62061 | SIL 3 |
|---|
Datos eléctricos
| insulation voltage rated value | 500 V |
|---|---|
| overvoltage category | III |
| surge voltage resistance rated value | 6 kV |
| consumed current maximum | 140 mA |
| number of poles for main current circuit | 3 |
| adjustable current response value current of the current | 0.9 ... 3 A |
| operating voltage rated value | 48 ... 500 V |
| relative symmetrical tolerance of the operating voltage | 10 % |
| operational current at AC at 400 V rated value | 3A |
| operating power for 3-phase motors at 400 V at 50 Hz | 0.37 ... 1.1 kW |
| input voltage at digital input at DC rated value | 24 V |
| input current at digital input for signal <1> typical | 0A |
| type of voltage of the supply voltage | DC |
| supply voltage at DC rated value | 24 V |
| inrush current peak at 24 V | 25 A; Observe the manual for group configuration |
| duration of inrush current peak at 24 V | 0.14 ms |
| when switched off via supply voltage maximum | 120 ms |
| for supply voltage line-side | Plug contact to Base Unit |
| full-load current (FLA) for 3-phase AC motor at 480 V rated | 3A |
| current with locked rotor (LRA) for 3-phase AC motor at 480 V | 24 A |
| operating voltage at AC at 60 Hz according to CSA and UL | 480 V |
Entradas/Salidas y comunicación
| PROFIBUS DP protocol | Yes |
|---|---|
| PROFINET protocol | Yes |
| type of electrical connection of the communication interface | Plug contact to Base Unit |
Condiciones ambientales
| vibration resistance | 15 mm to 6 Hz; 2 g to 500 Hz |
|---|---|
| installation altitude at height above sea level maximum | 4 000 m |
Prestaciones y durabilidad
| B10 value with high demand rate according to SN 31920 | 1 000 000 |
|---|
Otras características
| product brand name | SIMATIC |
|---|---|
| product category | Motor starter |
| product type designation | ET 200SP |
| equipment version according to IEC 60947-4-2 | 3 |
| product function | Fail-safe direct-on-line starter |
| on-site operation | Yes |
| remote firmware update | Yes |
| degree of pollution | 2 |
| between main and auxiliary circuit | 500 V |
| shock resistance | 6 g / 11 ms |
| operating frequency maximum | 1 1/s |
| type of coordination | 1 |
| according to IEC 60947-4-2 | AC-53a: 3 A: (8-0,7: 70-32) |
| Net Weight | 0.427 kg |
| direct start | Yes |
| EMC emitted interference according to IEC 60947-1 | class A |
| EMC immunity according to IEC 60947-1 | Class A |
| due to burst according to IEC 61000-4-4 | 3 kV |
| due to conductor-earth surge according to IEC 61000-4-5 | 4 kV |
| due to conductor-conductor surge according to IEC | 2 kV |
| due to high-frequency radiation according to IEC 61000 | Class A |
| field-based interference according to IEC 61000-4-3 | 20 V/m |
| electrostatic discharge according to IEC 61000-4-2 | 8 kV air discharge |
| conducted HF interference emissions according to | Class A for industrial environment |
| product function suitable for safety function | Yes |
| safety-related switching OFF | Yes |
| safe state | Load circuit open |
| test wear-related service life necessary | Yes |
| function test interval maximum | 0.083 a |
| stop category according to IEC 60204-1 | 0 |
| proportion of dangerous failures with high demand rate | 50 % |
| Safe failure fraction (SFF) | 99.5 % |
| design of the switching contact | Hybrid |
| minimum load [%] | 50 %; from smallest adjustable rated current |
| operating frequency 1 rated value | 50 Hz |
| operating frequency 2 rated value | 60 Hz |
| relative positive tolerance of the operating frequency | 5% |
| relative negative tolerance of the operating frequency | 5% |
| ampacity when starting maximum | 30 A |
| number of digital inputs | 5 |
| note | 4 via 3DI/LC module |
| safety-related | 1 |
| type of input characteristic | Type 1 in accordance with EN 61131-2 |
| minimum permissible | 20.4 V |
| maximum permissible | 28.8 V |
| ON-delay time | 35 ms |
| OFF-delay time | 35 ... 50 ms |
| when switched off via control inputs maximum | 55 ms |
| mounting position | Vertical, horizontal (observe derating) |
| fastening method | pluggable in BaseUnit |
| height | 142 mm |
| width | 30 mm |
| depth | 150 mm |
| upwards | 50 mm |
| downwards | 50 mm |
| 60721 | not get into the devices) |
| relative humidity during operation | 10 ... 95 % |
| air pressure according to SN 31205 | 900 ... 1 060 hPa |
| product function bus communication | Yes |
| supports PROFIenergy measured values | Yes |
| supports PROFIenergy shutdown | Yes |
| 1 for digital input signals | Pluggable module - accessory |
| 2 for digital input signals | Plug contact to Base Unit |
| for main energy infeed | Plug contact to Base Unit |
| for load-side outgoing feeder | Plug contact to Base Unit |
| wire length for motor unshielded maximum | 200 m |