Relé estático 3RF2, 30A, 110V DC
Siemens

Relé estático 3RF2, 30A, 110V DC

Producto descatalogado No disponible para compra · Sustituido por 3RF3330-2DA64
Contactor estático monofásico 3RF2 AC 51 / 30 A / 40 °c 48-460 V / 110 V DC a prueba de cortocircuitos hasta 25 A con automático B bornes de resorte

Conexión y cableado
product component removable terminal for auxiliary andYes
for AWG cables for main contacts2x (18 ... 14)
for AWG cables for auxiliary and control contacts1x (20 ... 12)
AWG number as coded connectable conductor cross18 ... 14
Condiciones ambientales
installation altitude at height above sea level maximum1 000 m
Otras características
product brand nameSIRIUS
design of the product1-pole
product type designation3RF23
_1 of the accessories that can be ordered3RF2900-3PA88
product functionshort-circuit resistant with B-automatic device
at AC in hot operating state33 W
at AC in hot operating state per pole33 W
without load current share typical1.1 W
insulation voltage rated value600 V
degree of pollution3
surge voltage resistance of main circuit rated value6 kV
protection class IPIP20
protection class IP on the front according to IEC 60529IP20
shock resistance according to IEC 60068-2-2715 g / 11 ms
vibration resistance according to IEC 60068-2-62g
Net Weight0.275 g
number of poles for main current circuit1
number of NO contacts for main contacts1
number of NC contacts for main contacts0
type of voltage of the operating voltageAC
at 50 Hz rated value48 ... 460 V
at 60 Hz rated value48 ... 460 V
operating frequency rated value50 ... 60 Hz
at 50 Hz40 ... 506 V
at 60 Hz40 ... 506 V
at AC-1 at 400 V rated value30 A
at AC-51 rated value30 A
at AC-51 according to IEC 60947-4-322 A
operational current minimum500 mA
operational current of the MCB at AC rated value25 A
rate of voltage rise at the thyristor for main contacts1 000 V/µs
blocking voltage at the thyristor for main contacts1 200 V
reverse current of the thyristor10 mA
derating temperature40 °C
surge current resistance rated value1 150 A
I2t value maximum6 600 A²·s
type of voltage of the control supply voltageDC
control supply voltage 1 at DC77 ... 110 V
full-scale value for signal<0> recognition40 V
control current at DC rated value10 mA
ON-delay time1 ms; additionally max. one half-wave
OFF-delay time1 ms; additionally max. one half-wave
fastening method side-by-side mountingYes
design of the thread of the screw for securing theM4
height95 mm
width22.5 mm
depth120 mm
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
solid2x (0.5 ... 2.5 mm²)
finely stranded with core end processing2x (0.5 ... 1.5 mm²)
finely stranded without core end processing2x (0.5 ... 2.5 mm²)
solid or stranded0.5 ... 2.5 mm²
of the auxiliary and control contactsM3
for main contacts10 mm
for auxiliary and control contacts10 mm
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
during operation-25 ... +60 °C
during storage-55 ... +80 °C
due to burst according to IEC 61000-4-42 kV / 5 kHz, behavior criterion 2
due to conductor-earth surge according to IEC 61000-4-52 kV, behavior criterion 2
due to conductor-conductor surge according to IEC1 kV, behavior criterion 2
due to high-frequency radiation according to IEC 61000140 dBuV in the frequency range 0.15 ... 80 MHz, behavior criterion 1
field-based interference according to IEC 61000-4-380 MHz ... 1 GHz 10 V/m, behavior criterion 1
electrostatic discharge according to IEC 61000-4-24 kV contact discharging / 8 kV air discharging, behavior criterion 2
conducted HF interference emissions according toClass A for industrial environment
of gS fuse for semiconductor protection at NH design3NE1803-0
of back-up R fuse link for semiconductor protection at3NC1032
at NH design usable noteThese fuses have a smaller rated current than the semiconductor relays
at cylindrical design 14 x 51 mm usable noteThese fuses have a smaller rated current than the semiconductor relays
at cylindrical design 22 x 58 mm usable noteThese fuses have a smaller rated current than the semiconductor relays
of DIAZED fuse usable noteThese fuses have a smaller rated current than the semiconductor relays
last modified:4/4/2026

Ficha técnica oficial del fabricante con todas las especificaciones.

Producto bajo pedido

Puedes pedirlo ya: te lo servimos en el plazo indicado. Selecciona la cantidad para añadirlo al carrito. Si prefieres esperar a que vuelva a haber stock inmediato, déjanos tu email abajo.

Plazo de entrega (días):

Este artículo va bajo pedido.

Avísame cuando esté disponible

Solo usaremos tu email para avisarte de este artículo.