Contactor SIRIUS Innovations, 5kW, S00, resorte
Siemens

Contactor SIRIUS Innovations, 5kW, S00, resorte

SIRIUS Innovations Contactor, AC-3, 7, 5KW/400v, 1NC, AC 24v, 50/60 Hz, S00 conexión resorte

Datasheet
Contactor SIRIUS Innovations, 5kW, S00, resorte
€49,22 EUR
€133,03 EUR
3RT2018-2AB02
Plazo de entrega (días):
€49,22 EUR /each
Total:

Especificaciones técnicas

product brand name SIRIUS
product designation Power contactor
product type designation 3RT2
size of contactor S00
auxiliary switch Yes
at AC in hot operating state 3W
at AC in hot operating state per pole 1W
without load current share typical 1.5 W
type of calculation of power loss current-dependent quadratic
of main circuit with degree of pollution 3 rated value 690 V
of auxiliary circuit with degree of pollution 3 rated value 690 V
of main circuit rated value 6 kV
of auxiliary circuit rated value 6 kV
maximum permissible voltage for protective separation between 400 V
at AC 7,3 g / 5 ms, 4,7 g / 10 ms
of contactor typical 30 000 000
of the contactor with added electronically optimized 5 000 000
of the contactor with added auxiliary switch block typical 10 000 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (day/month/year) 10/01/2009
Net Weight 0.254 g
installation altitude at height above sea level maximum 2 000 m
during operation -25 ... +60 °C
during storage -55 ... +80 °C
relative humidity minimum 10 %
relative humidity at 55 °C according to IEC 60068-2-30 95 %
number of poles for main current circuit 3
number of NO contacts for main contacts 3
number of NC contacts for main contacts 0
at AC-3 rated value maximum 690 V
at AC-3e rated value maximum 690 V
at AC-1 at 400 V at ambient temperature 40 °C rated 22 A
up to 690 V at ambient temperature 40 °C rated 22 A
up to 690 V at ambient temperature 60 °C rated 20 A
at 400 V rated value 16 A
at 500 V rated value 12.4 A
at 690 V rated value 8.9 A
at AC-4 at 400 V rated value 11.5 A
at AC-5a up to 690 V rated value 19.4 A
at AC-5b up to 400 V rated value 13.2 A
up to 230 V for current peak value n=20 rated value 9.6 A
up to 400 V for current peak value n=20 rated value 9.6 A
up to 500 V for current peak value n=20 rated value 9.6 A
up to 690 V for current peak value n=20 rated value 8.9 A
up to 230 V for current peak value n=30 rated value 6.6 A
up to 400 V for current peak value n=30 rated value 6.4 A
up to 500 V for current peak value n=30 rated value 6.4 A
up to 690 V for current peak value n=30 rated value 6.4 A
minimum cross-section in main circuit at maximum AC-1 rated 4 mm²
at 24 V rated value 20 A
at 60 V rated value 20 A
at 110 V rated value 2.1 A
at 220 V rated value 0.8 A
at 440 V rated value 0.6 A
at 600 V rated value 0.6 A
at 230 V rated value 4 kW
limited to 1 s switching at zero current maximum 300 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum 169 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum 128 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum 92 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum 74 A; Use minimum cross-section acc. to AC-1 rated value
at AC-1 maximum 1 000 1/h
at AC-2 maximum 750 1/h
at AC-3 maximum 750 1/h
maximum 750 1/h
at AC-4 maximum 250 1/h
type of voltage of the control supply voltage AC
at 50 Hz rated value 24 V
at 60 Hz rated value 24 V
at 50 Hz 0.8 ... 1.1
at 60 Hz 0.85 ... 1.1
arcing time 10 ... 15 ms
control version of the switch operating mechanism Standard A1 - A2
number of NC contacts for auxiliary contacts instantaneous 1
number of NO contacts for auxiliary contacts instantaneous 0
operational current at AC-12 maximum 10 A
at 48 V rated value 6A
at 125 V rated value 2A
contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
at 480 V rated value 14 A
at 110/120 V rated value 1 hp
at 200/208 V rated value 3 hp
at 220/230 V rated value 5 hp
at 460/480 V rated value 10 hp
at 575/600 V rated value 10 hp
contact rating of auxiliary contacts according to UL A600 / Q600
design of the miniature circuit breaker for short-circuit protection C characteristic: 10 A; 0.4 kA
for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA)
fastening method side-by-side mounting Yes
height 70 mm
width 45 mm
depth 73 mm
forwards 10 mm
upwards 10 mm
downwards 10 mm
at the side 0 mm
for main current circuit spring-loaded terminals
for auxiliary and control circuit spring-loaded terminals
at contactor for auxiliary contacts Spring-type terminals
of magnet coil Spring-type terminals
solid 2x (0.5 ... 4 mm²)
solid or stranded 2x (0,5 ... 4 mm²)
finely stranded with core end processing 2x (0.5 ... 2.5 mm²)
finely stranded without core end processing 2x (0.5 ... 2.5 mm²)
for AWG cables for main contacts 2x (20 ... 12)
stranded 0.5 ... 4 mm²
for AWG cables for auxiliary contacts 2x (20 ... 12)
AWG number as coded connectable conductor cross 20 ... 12
mirror contact according to IEC 60947-4-1 Yes
suitable for safety function Yes
suitability for use safety-related switching OFF Yes
service life maximum 20 a
test wear-related service life necessary Yes
with low demand rate according to SN 31920 40 %
with high demand rate according to SN 31920 73 %
B10 value with high demand rate according to SN 31920 1 000 000
failure rate [FIT] with low demand rate according to SN 100 FIT
device type according to ISO 13849-1 3
overdimensioning according to ISO 13849-2 necessary Yes
safety device type according to IEC 61508-2 Type A
protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front
global warming potential [CO2 eq] / during manufacturing 1.18 kg
global warming potential [CO2 eq] / during operation 38.5 kg
global warming potential [CO2 eq] / after end of life -0.155 kg
global warming potential [CO2 eq] / total 39.6 kg
Maritime application other
other Railway
last modified: 4/4/2026