Contactor, 12A, 5,5kW, 220V AC, tam. S00, resorte
Siemens

Contactor, 12A, 5,5kW, 220V AC, tam. S00, resorte

Contactor de potencia, AC-3e/AC-3, 12 A, 5,5 kW/400 V, tripolar, 220 V AC, 50/60 Hz, contactos auxiliares: 1 NC, borne de resorte, tamaño: S00

Protección y seguridad
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
safety device type according to IEC 61508-2Type A
Conexión y cableado
size of contactorS00
of contactor typical30 000 000
of the contactor with added electronically optimized5 000 000
of the contactor with added auxiliary switch block typical10 000 000
at contactor for auxiliary contactsSpring-type terminals
for AWG cables for main contacts2x (20 ... 12)
for AWG cables for auxiliary contacts2x (20 ... 12)
AWG number as coded connectable conductor cross20 ... 12
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
at AC-1 at 400 V at ambient temperature 40 °C rated22 A
up to 690 V at ambient temperature 40 °C rated22 A
up to 690 V at ambient temperature 60 °C rated20 A
Prestaciones y durabilidad
B10 value with high demand rate according to SN 319201 000 000
Otras características
product brand nameSIRIUS
product type designation3RT2
auxiliary switchYes
at AC in hot operating state1.5 W
at AC in hot operating state per pole0.5 W
without load current share typical1.5 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
at AC7,3 g / 5 ms, 4,7 g / 10 ms
Net Weight0.257 g
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-3095 %
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at 400 V rated value12 A
at 500 V rated value9.2 A
at 690 V rated value6.7 A
at AC-4 at 400 V rated value8.5 A
at AC-5a up to 690 V rated value19.4 A
at AC-5b up to 400 V rated value9.9 A
up to 230 V for current peak value n=20 rated value7.2 A
up to 400 V for current peak value n=20 rated value7.2 A
up to 500 V for current peak value n=20 rated value7.2 A
up to 690 V for current peak value n=20 rated value6.7 A
up to 230 V for current peak value n=30 rated value4.8 A
up to 400 V for current peak value n=30 rated value4.8 A
up to 500 V for current peak value n=30 rated value4.8 A
up to 690 V for current peak value n=30 rated value4.8 A
at 24 V rated value20 A
at 60 V rated value20 A
at 110 V rated value2.1 A
at 220 V rated value0.8 A
at 440 V rated value0.6 A
at 600 V rated value0.6 A
at AC-2 at 400 V rated value5.5 kW
at 230 V rated value3 kW
limited to 1 s switching at zero current maximum200 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum123 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum96 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum74 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum61 A; Use minimum cross-section acc. to AC-1 rated value
at AC-1 maximum1 000 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
maximum750 1/h
at AC-4 maximum250 1/h
type of voltage of the control supply voltageAC
at 50 Hz rated value220 V
at 60 Hz rated value220 V
at 50 Hz0.8 ... 1.1
at 60 Hz0.85 ... 1.1
arcing time10 ... 15 ms
control version of the switch operating mechanismStandard A1 - A2
operational current at AC-12 maximum10 A
at 48 V rated value6A
at 125 V rated value2A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
at 480 V rated value11 A
at 110/120 V rated value0.5 hp
at 200/208 V rated value3 hp
at 220/230 V rated value3 hp
at 460/480 V rated value8 hp
at 575/600 V rated value10 hp
contact rating of auxiliary contacts according to ULA600 / Q600
fastening method side-by-side mountingYes
height70 mm
width45 mm
depth73 mm
forwards10 mm
upwards10 mm
downwards10 mm
at the side0 mm
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
of magnet coilSpring-type terminals
solid2x (0.5 ... 4 mm²)
solid or stranded2x (0,5 ... 4 mm²)
finely stranded with core end processing2x (0.5 ... 2.5 mm²)
finely stranded without core end processing2x (0.5 ... 2.5 mm²)
stranded0.5 ... 4 mm²
mirror contact according to IEC 60947-4-1Yes
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
failure rate [FIT] with low demand rate according to SN100 FIT
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
otherRailway
3/L25/L3