Contactor, 12A, 5,5kW, 21-28V AC, tam. S0, tornillo
Siemens

Contactor, 12A, 5,5kW, 21-28V AC, tam. S0, tornillo

Contactor de potencia, AC-3e/AC-3, 12 A, 5,5 kW/400 V, tripolar, 21-28 V AC/DC, 50/60 Hz, con varistor integrado, contactos auxiliares: 1 NA + 1 NC, borne de tornillo, tamaño: S0

Protección y seguridad
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
safety device type according to IEC 61508-2Type A
Conexión y cableado
size of contactorS0
of contactor typical10 000 000
of the contactor with added electronically optimized5 000 000
of the contactor with added auxiliary switch block typical10 000 000
at contactor for auxiliary contactsScrew-type terminals
for AWG cables for main contacts2x (16 ... 12), 2x (14 ... 8)
for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
AWG number as coded connectable conductor cross16 ... 8
Condiciones ambientales
installation altitude at height above sea level maximum2 000 m
at AC-1 at 400 V at ambient temperature 40 °C rated40 A
up to 690 V at ambient temperature 40 °C rated40 A
up to 690 V at ambient temperature 60 °C rated35 A
Prestaciones y durabilidad
B10 value with high demand rate according to SN 319201 000 000
Otras características
product brand nameSIRIUS
product type designation3RT2
auxiliary switchYes
at AC in hot operating state0.9 W
at AC in hot operating state per pole0.3 W
without load current share typical1.4 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
at AC7,5 g / 5 ms, 4,7 g / 10 ms
at DC10g / 5 ms, 7,5g / 10 ms
Net Weight0.577 g
during operation-25 ... +60 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-3095 %
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at 400 V rated value12 A
at 500 V rated value12 A
at 690 V rated value9A
at AC-4 at 400 V rated value12.5 A
at AC-5a up to 690 V rated value35.2 A
at AC-5b up to 400 V rated value9.9 A
up to 230 V for current peak value n=20 rated value11.4 A
up to 400 V for current peak value n=20 rated value11.4 A
up to 500 V for current peak value n=20 rated value11.3 A
up to 690 V for current peak value n=20 rated value9A
up to 230 V for current peak value n=30 rated value7.6 A
up to 400 V for current peak value n=30 rated value7.6 A
up to 500 V for current peak value n=30 rated value7.6 A
up to 690 V for current peak value n=30 rated value7.6 A
at 24 V rated value35 A
at 60 V rated value20 A
at 110 V rated value4.5 A
at 220 V rated value1A
at 440 V rated value0.4 A
at 600 V rated value0.25 A
at 230 V rated value3 kW
limited to 1 s switching at zero current maximum210 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum210 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum170 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum126 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum105 A; Use minimum cross-section acc. to AC-1 rated value
at AC-1 maximum1 000 1/h
at AC-2 maximum1 000 1/h
at AC-3 maximum1 000 1/h
maximum1 000 1/h
at AC-4 maximum300 1/h
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value21 ... 28 V
at 60 Hz rated value21 ... 28 V
control supply voltage at DC rated value21 ... 28 V
initial value0.7
full-scale value1.3
at 50 Hz0.7 ... 1.3
at 60 Hz0.7 ... 1.3
design of the surge suppressorwith varistor
inrush current peak3A
duration of inrush current peak30 µs
pickup current mean value0.3 A
pickup current peak0.52 A
duration of pickup current180 ms
holding current mean value45 mA
at minimum rated control supply voltage at DC1.4 VA
at maximum rated control supply voltage at DC1.4 VA
closing power of magnet coil at DC5.9 W
holding power of magnet coil at DC1.4 W
arcing time10 ms
control version of the switch operating mechanismStandard A1 - A2
operational current at AC-12 maximum10 A
at 48 V rated value6A
at 125 V rated value2A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
at 480 V rated value11 A
at 110/120 V rated value1 hp
at 200/208 V rated value3 hp
at 220/230 V rated value3 hp
at 460/480 V rated value8 hp
at 575/600 V rated value10 hp
contact rating of auxiliary contacts according to ULA600 / P600
UL File Number (CCN)E31519 (NLDX, NLDX7)
fastening method side-by-side mountingYes
height85 mm
width45 mm
depth107 mm
forwards10 mm
upwards10 mm
downwards10 mm
at the side0 mm
for main current circuitscrew-type terminals
for auxiliary and control circuitscrew-type terminals
of magnet coilScrew-type terminals
solid2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
stranded1 ... 10 mm²
mirror contact according to IEC 60947-4-1Yes
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
failure rate [FIT] with low demand rate according to SN100 FIT
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
ateates/Test Report
otherRailway
3/L25/L3
13 NO21 NC
last modified:4/4/2026
⬇ Descargar datasheet (PDF)

Ficha técnica oficial del fabricante con todas las especificaciones.

Material con posibilidad de devolución
Contactor, 12A, 5,5kW, 21-28V AC, tam. S0, tornillo
€83,21 EUR
€224,89 EUR
3RT2024-1NB30
Plazo de entrega (días):
€83,21 EUR /each
Total:

Accesorios